5.CHECK WATER LEVEL
5.
Turn on water supply check for leaks.
Float
6
Fig. #5
5
Make sure the arrow on the green float on the white flush
6
valve is secure and pointing to # 6 .
6. MINOR ADJUSTMENT OF WATER
6.
Snap
LEVEL
Move the snap along "OPEN" direction.
OPEN
Fig.#6a
6a
To lower water level: Move water cup
down to a proper height and rotate
Screw
screw anticlockwise to achieve the
desired water level. (Refer to float
adjustment instructions.)
Fig.#6b
6b
To elevate water level: Rotate screw
clockwise and raise float to the desired
water level. Elevate water cup to a
proper position as well. (Refer to float
adjustment instructions.)
Fig.#6c
6c