Download Print this page
Bradford White E32-120R User Manual
Bradford White E32-120R User Manual

Bradford White E32-120R User Manual

Conversion kit instructions
Hide thumbs Also See for E32-120R:

Advertisement

Conversion Kit Instructions
For Models: E32-50S, E32-80R, & E32-120R
(To be performed ONLY by qualified service providers)
238-43984-00B 1/10

Advertisement

loading

Summary of Contents for Bradford White E32-120R

  • Page 1 Conversion Kit Instructions For Models: E32-50S, E32-80R, & E32-120R (To be performed ONLY by qualified service providers) 238-43984-00B 1/10...
  • Page 2 NOT be attempted. These conversion kits are only applicable to Models E32-50S / E32-80R / E32-120R. The following information is provided to assist in the successful conversion of the water heater: Safety precautions ...3...
  • Page 3 Be sure to disconnect the water heater from the electrical supply before performing any servicing of the electrical system or before attempting any of the conversion procedures. Never perform servicing of the electrical system or any of the conversion procedures with wet hands or when you are in contact with water that is on the floor or in the vicinity of the water heater.
  • Page 4 Instructions for Conversion of Commercial Electric Models Conversion Kits for Models E32-50S-3/80R-3/120R-3 1. Refer to Table 1 below that contains water heater KW, Element Wattage, Voltage, and kit part numbers. 2. Locate the KW of the required water heater. 3. Move across the table (to the right) until you reach the required voltage.
  • Page 5 Instructions for Conversion of Commercial Electric Models Wattage/Voltage Conversion --- Element Changes 1. Remove and replace one element at a time. 2. Disconnect the electrical wires from the element terminals. 3. Remove the electrical elements using the Screw-in element removal wrench --- or ---- a 1 ½” deep well socket wrench.
  • Page 6 Use caution to not damage any of the wire insulation when removing control box. 3. Install new control box onto the water heater by feeding the wires through the back of the control box and reinstall (4) mounting screws. 4. Reconnect wires to new fuse blocks. Be certain to match wire colors to Line side of fuse blocks.
  • Page 7 3. Connect blue wire to terminal L-2 of the terminal block. The red wires should remain connected to L-2 of the terminal block as it was originally manufactured. 4. Field wiring for the water heater power supply will eventually be connected to the line terminals L-1 and L-2 of the terminal block when the product is installed.
  • Page 8 Instructions for Conversion of Commercial Electric Models Phase Conversion Only kits Conversion Volts 265-45246-13 265-45246-07 265-45246-01 13.5KW Conversion Volts 265-45246-16 265-45246-10 265-45246-04 Recheck and inspect to make certain all components involved in the conversion are correct and secure. Recheck all of the electrical wiring changes made against the wiring diagram requirements for accuracy. Check to insure all of the electrical connections are tightly secured and the electrical wire routings are orderly.
  • Page 9 Replace all insulation pieces and element covers that were removed. Replace the electrical enclosure door. Heater identification information that was placed on the water heater carton must also be altered. This can be done by making a bold face inscription on the carton with a large size black ink marker. Write the new...
  • Page 10 NOTES...
  • Page 11 NOTES...
  • Page 12 Ambler, PA For U.S. and Canada field service, Contact your professional installer or local Bradford White representative. Sales/800-523-2931 Fax/215-641-1670 Parts Fax/215-641-2180 Technical Support/800-334-3393 Fax/269-795-1089 Warranty/800-531-2111 Fax/269-795-1089 International: Telephone/215-641-9400 Telefax/215-641-9750 Mississauga, ON Sales/866-690-0961 905-238-0100 Fax/905-238-0105 Technical Support/800-334-3393 Email parts@bradfordwhite.com techserv@bradfordwhite.com www.bradfordwhite.com...

This manual is also suitable for:

E32-50sE32-80r