Bradford White eF Series Troubleshooting Manual And Instructions For Service page 7

Ultra high efficiency water heater
Table of Contents

Advertisement

Features of ICON System Module
Water heater digital display on control board for setting and displaying the temperature setpoint. Pressing
temperature UP and DOWN buttons changes the temperature setpoint. Temperature format may be
displayed in °F or °C.
Single control board with plug in wiring controls temperature, ignition, and blower operation.
Plug in wiring reduces chance of miswiring.
Burner ignition with direct spark ignition – A high voltage spark jumps from the spark rod to the burner
surface to ignite the gas.
Water heater digital display will show diagnostic codes in the event the water heater needs servicing. Aids
in diagnosing and servicing the water heater.
Water heater digital display can show previous error code history to further aid in servicing the water heater.
Power Supply
Gas Supply
Approved Gas Type
Gas Pressure (Nat &
L.P.)
Venting System
Approved Vent
Materials
Minimum Clearance
for Servicing
Maximum Water
Supply Pressure
Thermostat Sensor
Control Display
Control Board
Transformer
Spark Rod Igniter
Flame Sensor Output
Gas Valve
Vent Safety Switch
Blocked Vent
Pressure Switch
Blower
Icon System
Dedicated 120 VAC, 60 Hz, 15A
Minimum ¾" NPT
(schedule 40 black iron pipe recommended)
Natural or Propane. Unit must match gas type supplied.
14.0" W.C. maximum static, 4.5" W.C. minimum running (recommend 7.0" W.C.
min running)
Power vent, balanced direct vent or unbalanced direct vent. See vent tables on
page 8.
PVC, CPVC, Polypropylene, or Stainless Steel
18" from top, 24" from front, 4" sides and rear.
150 PSI
11,900 Ohms @ 70°F, ECO opens @ 207°F Max., ECO close @ 120°F Min.
Redundant sensor for ECO. Sensor inside well for easy replacement of
Digital display, 24 volts. Temperature Range: 70-180°F. Used to set tank
temperature (°F or °C), show operating status, display error codes, error code
history, limit maximum setpoint temperature.
Operates from 24 volt from transformer. Controls tank temperature, ignition
functions, combustion blower. See ignition timings in sequence of operation
for SOLA Control.
120VAC primary, 24VAC secondary, 40VA.
0.22" nominal gap to the burner surface.
Minimum 1 micro amp, typical range 5 to 30 micro amps.
Negative regulation, 24 VAC, ½" PSI max., 4.5" W.C. Minimum running inlet.
Normally closed, opens @ 350°F, manual reset.
24VAC, normally closed, opens when pressure increases to +2.70 W.C.
120VAC, 60Hz, 1-4 amps
7
7