Table 4-8 Command Syntax; Table 4-9 Supported Commands (Per Tia Pn2388 8/20/90) - ZyXEL Communications OMNI 56K Plus Series User Manual

Data/fax modem
Table of Contents

Advertisement

VALUE
74
96
97
98
121
122
145
146
4.2.2 Service Class 2 Commands
The following Class 2 commands are supported and implemented as per TIA PN2388 (8/20/90):
COMMAND SYNTAX
+<command>=<value>
+<command>=?
+<command>?

Table 4-9 Supported Commands (per TIA PN2388 8/20/90)

COMMAND
+FAA=n
Auto-answer mode parameter:
Answer as set by +FCLASS.
DCE answers and auto-determines type.
+FBADLIN= <value>
Bad line threshold (number of consecutive bad lines for a bad page
parameter):
Determine if Copy Quality OK on the T.30 flow chart. <value>=0 to
255; a value of 0 implies that error checking is disabled.
+FBOR=n
Phase C data bit order:
Select direct bit order.
Select reversed bit order in receiving mode for phase C data.
+FBUF?
Buffer size; read only parameter:
Allow DTE to determine the characteristics of the DCE's buffer size.
+FCIG="string"
Local fax station ID string, for polling Rx.
+FCLASS=n
Service class selection: Refer to +FCLASS Class 1 command in
previous section.
+FCON
DCE responds fax connection.
+FCQ=n
Copy quality check capability parameter
No copy quality check capability.
Command Sets
Table 4-7 The Value of <MOD> Parameters
MODULATION
V.17 short train
V.29
V.17
V.17 short train
V.17
V.17 short train
V.17
V.17 short train

Table 4-8 Command Syntax

Execute a command or set a parameter.
Read permissible settings.
Read current setting.
DESCRIPTION
Omni 56K Plus Series User's Guide
SPEED
7200
9600
9600
9600
12000
12000
14400
14400
DESCRIPTION
VALUE
n=0
n=1
0-255
n=0
n=1
n=0
4-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents