Repair; Reading Out Internal Appliance Data - Bosch TCA640 Series Repair Instruction

Fully-automatic coffeemaker
Table of Contents

Advertisement

6

REPAIR

6.1

Reading out internal appliance data

This function can display saved data:
Appliance is in standby mode.
Simultaneously press and hold down the clean and calc
buttons for approx. 4 seconds.
Displays indicate in succession the software version, the serial
number, the appliance number, the last service date and the
production date. Then the appliance switches back to standby
mode.
Appliance version
Software version
58300000120060_ARA_en_c.doc – 18.09.09
Flash
Model number
Version
Production date
If the electronics module or the display does not support this function
in the event of a fault, the current state of the appliance can be
determined by the labelling on the rear of the display and the logic
board (control module).
Note:
For number of brews see under "Change programming, standard
settings".
Parameter version
Production date of
electronics module
Seite 51 von 95