Front Panel description

Front Panel Description
Online Page Description
Parameter
Ke y Press
Ke y
Displays line to neutral voltage of 3 phases.
Displays line to line voltage of 3 phases.
Displays % THD of line to neutral voltage of 3 phases.
Displays % THD of line to line voltage of 3 phases.
Displays current of 3 phases.
Displays % THD of current of 3 phases.
Displays line to neutral avg. voltage, current & frequency.
Press (
)
OK
Displays line to line avg. voltage, current & frequency.
key
(1st time)
Displays power factor of 3 phases.
Displays active power of 3 phases.
Press (
)
OK
Displays reactive power of 3 phases.
key
(2nd time)
Displays apparent power of 3 phases.
Displays active energy.
Press (
)
OK
Displays apparent energy.
key
Displays reactive energy.
(3rd time)
Displays temperature.*
Parameter
Ke y Press
Key
Displays line to line voltage of 3 phases.
Displays % THD of line to line voltage of 3 phases.
Displays current of 3 phases.
Displays % THD of current of 3 phases.
Press (
)
Displays line to line avg. voltage, current & frequency.
OK
key
Displays avg. power factor of 3 phases.
(1st time)
Displays total active power.
OK
)
Press (
Displays total reactive power.
key
(2nd time)
Displays total apparent power.
Displays active energy.
Displays apparent energy.
Press (
)
OK
)
key
Displays reactive energy.
(3rd time)
Displays temperature.*
Parameter
Ke y Press
Ke y
Displays line to neutral voltage of 1st phase.
Displays % THD of line to neutral voltage of 1st phase.
Displays current of 1st phase.
Displays % THD of current of 1st phase.
Press (
)
OK
Displays power factor of 1st phase & frequency.
key
(1st time)
Displays active power of 1st phase.
Press (
)
OK
Displays reactive power of 1st phase.
key
(2nd time)
Displays apparent power of 1st phase.
Displays active energy of 1st phase.
NOTE : *Temperature will be displayed when over temp setting is 'ON'.
Displays apparent energy of 1st phase.
Press (
)
OK
key
Displays reactive energy of 1st phase.
(3rd time)
Displays temperature.*
Key Description
For 3 sec. to enter or exit
Press
&
OK
from the configurationmenu.
Press
For increment
To move cursor right by
Press
one digit each time after
last digit of display cursor
shift at 1st digit of display.
To save the setting and
Press
OK
move on to next page
Press
To go back
ESC
Description For 3P4W
Description For 3P3W
Description For 1P2W

Test Mode

Press
&
for 3 Sec. to enter in Test Mode.
ESC
NOTE : Test mode checks all the relays present in product sequentially.
Parameter
Turn ON DI manually when the DI CHECK page is displayed. DI status
Ke y Press
Ke y
will be displayed & returns to online page.
Displays line to neutral voltage of 1st phase.
Configuration
Displays % THD of line to neutral voltage of 1st phase.
There are 4 dedicated keys
,
OK
Displays current of 1st phase.
Use these 4 keys to enter into configuration menu / change setting.
NOTE : The setting should be done by a professional after going through this
Displays % THD of current of 1st phase.
operating manual.
Press (
)
OK
Serial Number Description
Displays power factor of 1st phase & frequency.
key
(1st time)
(
)
Press ESC
key for 10sec.
ESC
Displays active power of 1st phase.
to display 8 digit serial number
Press (
)
OK
at 2 & 3 line of display.
nd
rd
Displays reactive power of 1st phase.
key
(2nd time)
Displays apparent power of 1st phase.
Displays active energy of 1st phase.
Displays apparent energy of 1st phase.
Press (
)
OK
key
Displays reactive energy of 1st phase.
(3rd time)
Displays temperature.*
Parameter
Ke y Press
Key
Displays line to neutral voltage of 1st phase.
Displays % THD of line to neutral voltage of 1st phase.
Displays current of 1st phase.
Displays % THD of current of 1st phase.
Press (
)
OK
Displays power factor of 1st phase & frequency.
key
(1st time)
Displays active power of 1st phase.
Press (
)
OK
Displays reactive power of 1st phase.
key
(2nd time)
Displays apparent power of 1st phase.
Displays active energy of 1st phase.
Displays apparent energy of 1st phase.
Press (
)
OK
key
Displays reactive energy of 1st phase.
(3rd time)
Displays temperature.*
Parameter
Ke y Press
Ke y
Displays line to line voltage.
Displays % THD of line to line voltage.
Displays current.
Displays % THD of current.
Press (
)
OK
Displays power factor and frequency.
key
(1st time)
Displays total active power.
Press (
)
OK
Displays total reactive power.
key
(2nd time)
Displays total apparent power.
Displays active energy.
Displays apparent energy.
Press (
)
OK
key
Displays reactive energy.
(3rd time)
Displays temperature.*
Backlight Indications
Backlight
White
Capacitor Banks that are ON.
In Healthy condition
Fault condition occurred
Orange
Backlight turn to white again when user will press ESC key in
fault condition. Trip parameters will be displayed for 3sec each.
NOTE : On occurrence of any new fault condition backlight turns Orange & on pressing
ESC
key all trip parameters will be displayed for 3sec each.
CT Error
If current connection is reversed, meter will show in which phase connection
is reversed. If more than one phase reverse, it will display combination of
both.1 - 1st phase, 2 - 2nd phase, 3 - 3rd phase
Description For 1P2W
,
,
.
ESC
Online Page Mode Discription
AUTO / MANUAL / DEFAULT MODE:
Press OK (
) key for 3sec. to
OK
change online page mode.
Description For 1P2W
Description For 2P2W
Description
[Press E
SC
key to display trip parameter]