TRANSMISSION OIL LEVEL CHECKING
A. Transmission oil level
Keeping the motorbike level and in a vertical position, check
the oil level through the inspection (1) window on the right
crankcase. Check if level (a) is about midway of the inspec-
tion porthole.
To fill up, remove the filler cap (2).
Note*: Have this operation made with warmed-up
engine.
WARNING*: Be careful not to touch hot
engine oil
TRANSMISSION OIL CHANGE
To completely replace the oil, unscrew the plug (A) under the
oil sump and let oil come out, then screw the plug again with its
gasket and pour fresh oil from the hole of the loading plug.
Use only the prescribed quantity and type of oil (see on page
8)
Note:
Have this operation made with warmed-up
engine.
A: Draining plug
COOLANT LEVEL CHECK
Check level (1) in right-hand radiator when engine is cold (place
the motorcycle so that it is perpendicular to the ground). The
coolant should be approximately 10 mm above cells.
The radiator cap is provided of two unlocking positions, the
first being for the previous pressure discharge in the cooling
system.
WARNING
Avoid removing radiator cap when engine
is hot, as coolant may spout out and cause
scalding.
NOTE
Difficulties may arise in eliminating coolant
from varnished surfaces. If this occurs, wash
off with water.