Zanussi easyChill 110022 Specifications

100 kg-20 gn 1/1 active blast chiller / freezers

Advertisement

Quick Links

RANGE
COMPOSITION
Chilling means bringing the temperature of
cooked food from +90ºC to +3°C in a short
time lap to minimize bacteria proliferation and
avoid loss of food consistency and texture.
The ZANUSSI easyChill Blast
Chillers/Freezers reduce temperature to
+3°C at food core in less than 90 minutes
and down to -18°C in less than four hours.
After the Blast Chilling a holding cycle starts
automatically to respectively maintain food at
+3°C and -18°C. Blast freezed food has a
solid 6 months/1 year shelf life without loss of
flavour, nutritional values and weight. The
opportunity to prepare in a single shot the
food to be used in different times during the
week enables a better work scheduling and
therefore a sensible reduction in labour costs.
FUNCTIONAL AND
CONSTRUCTION
FEATURES
Soft Chilling (Air temperature
–2°C).
Hard Chilling (Air temperature
–20°C).
All the probe-driven cycles feature
ARTE (Algorithm for Remaining
Time Estimation): the machine
displays the actual time needed to
end the cycle and to make planning
the activities easier.
Holding at +3°C (automatically
activated at the end of each cycle).
Turbo cooling: the chiller works
continuously at the desired
temperature. Ideal for continuous
production and for pastry application.
Automatic recognition of the
insertion of the food probe (cycles
piloted either by food probe
temperature or by time)
Single sensor core probe as
standard.
ACTIVE BLAST CHILLER / FREEZERS
TECHNICAL DATA
CHARACTERISTICS
Power supply
Productivity per cycle - kg.
NF Regulations - chilling / freezing
UK Guide lines - chilling / freezing
Cooling unit
External dimensions - mm
width
depth/with open doors
height
Internal dimensions - mm
width
depth
height
N° and type of door
Door hinges
Trays type
Max load capacity - trays h 65 mm - n°
Compressor power - HP
N° defrost in 24 hrs.
Refrigerant type
Refrigeration power - W
Refrigerant power
at evaporation temperature - °C
Power - kW
installed-electric
Noise level - dBA
Net weight - kg.
Power supply - V, phases, Hz
INCLUDED ACCESSORIES
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER
100 KG-20 GN 1/1
BCF100A
110022
Electric
72, 72
100, 85
Built-In
1000
1285, 2099
2471
700
554
1850
1
Right Side
GN 1/1; 600x400
20
4,7;
3/30'
R404a;
7265
-10
7.47
68
300
400 V, 3N, 50
1
110022
ZANUSSI
P R O F E S S I O N A L
MODELS
BCF100RA
110024
Electric
72, 72
100, 85
Remote
1000
1285, 2099
2232
700
554
1850
1
Right Side
GN 1/1; 600x400
20
minimum 4,7;
3/25'
R404a;
5350
-30
0.88
65
190
400 V, 3N, 50
1

Advertisement

loading

Summary of Contents for Zanussi ZANUSSI easyChill 110022

  • Page 1 +90ºC to +3°C in a short time lap to minimize bacteria proliferation and avoid loss of food consistency and texture. The ZANUSSI easyChill Blast Chillers/Freezers reduce temperature to +3°C at food core in less than 90 minutes and down to -18°C in less than four hours.
  • Page 2 PC connection as accessory, gate � RS 485. No water connections required: Waste water can be plumbed into drain, but can also be collected in an optional waste container. ZANUSSI P R O F E S S I O N A L www.zanussiprofessional.com...
  • Page 3 The Company reserves the right to alter technical specifications without prior notice. ACTIVE BLAST CHILLER / FREEZERS 100 KG-20 GN 1/1 110022 BCF100A 110022 1" 3/4" 400 V, 3N, 50 ZANUSSI P R O F E S S I O N A L www.zanussiprofessional.com...
  • Page 4 The Company reserves the right to alter technical specifications without prior notice. ACTIVE BLAST CHILLER / FREEZERS 100 KG-20 GN 1/1 110024 BCF100RA 110024 3/4" 400 V, 3N, 50 ZANUSSI P R O F E S S I O N A L www.zanussiprofessional.com...

This manual is also suitable for:

Easychill 110024Easychill bcf100aEasychill bcf100ra