• We recommend you use a new length of
6mm
twin core earthed cable to ensure your
2
safety.
• Make connection by proceeding as follows: -
L
L
Note: Blanking plates not to be removed.
Ensure that the links are fitted as shown
• Pre-form wires to the appropriate shape to
suit fitting into the mains terminal block.
• Strip inner insulation on wires using wire
strippers.
• Twist the bared wires using pliers.
• Cut bared wires 10mm away from the end of
the inner insulation.
• Where uninsulated Earth wires are used
ensure they are suitably sheathed to leave
10mm bare wire to fit into the terminal.
• Clamp bare wires into the relevant terminal
and check they are held by tugging each one
in turn.
• Ensure all screws are securely tightened.
• Clamp the mains cable securely ensuring
5mm of the outer insuation is inside the
terminal block and that the wires are not taut
but not so slack as to cause any fouling.
• Connect the remaining end of the mains
cable to the appliance to the appliance point
/ junction box.
• Place fuse / miniature circuit breaker in
circuit and switch on at mains.
N
N
N
• When refitting the mains terminal cover,
ensure that the lower tabs are located inside
the bottom edge of the aperture, before
fixing the two screws into the top edge of the
mains terminal cover.
• Ensure that the cover is securely fastened.
Note: House circuit
Earth leakage / continuity tests must be carried
out before the appliance is connected to the
mains supply and re-checked after fitting.