PROGRAMMING THE SENSOR
REMOTE CONTROL SET-UP
Use of the remote control should be within 10 – 15 feet of the sensor.
"Door Closed" and "Door Open" patterns are independently adjustable. It is necessary to adjust the pattern
for a closed door, and then to adjust the pattern again when the door is open. The following functions may be
independently adjusted for each door position:
• Sensitivity
• Pattern width
• Pattern depth
The following functions apply to both "Door Closed" and "Door Open" positions:
• Auto-Learn time
• Immunity ("medium" and "high" affect interpretation of objects in detection field relative to background;
Learn time is unaffected)
• Frequency
• Output configuration
• Door control mode
• Hold time
• Interface type
NUMBER KEYS (0 – 9)
assign value for given
function
INTERFACE
1: New Style
2: LO21 – Old Style (LO21B/K/P/S/U,
LO-LINX, MC15, DP-HUB)
UNLOCK / INQUIRE / LOCK
To UNLOCK the sensor:
Press UNLOCK key once. Red LED flashes slowly. If
flashing fast, see Note below.
To LOCK the sensor:
Press LOCK key twice OR press once, then enter
a 4-digit lock code. If less than 4 digits, press
lock again after the last digit. LED goes out when
complete.
To INQUIRE the sensor:
Unlock sensor, press desired function key, then
press INQUIRY key – number of green flashes
corresponds to the value.
NOTE: If sensor is locked, and code is unknown,
power sensor off and then back on. Press UNLOCK
key within 60 seconds. Re-lock with 0000 (default
code). Sensor will unlock with one press of UNLOCK
key when set to 0000.
75.5905.06 BODYGUARD-T 20190402
ALL functions are programmable using the remote control.
Sensitivity
Pattern Width
Hold Time
Output Config
Pattern Depth
see next page for specific parameter settings
MODES OF OPERATION
0: Normal
1: MP Mode
2: Record Mode
INFRARED FREQUENCY
Mode
1
normal
2
normal
3
quiet
4
quiet
See Quiet Mode note on next page.
DOOR CONTROL
1: Normal (LED in normal mode)
2: Door permanently open
(red LED on)
3: Door permanently closed
(red LED off)
Auto-Learn Time
Immunity
Set-up
Frequency
low
high
low
high
Page 7 of 12