Installation

This extractor hood is intended to be
mounted onto the kitchen wall.
Open glass aperture.
1. Remove the grease filter (refer to
operating; Instructions).
2. Draw a line on the wall from the ceiling to
the lower edge of the hood at the centre of
the location where the hood is going to be
mounted.
Tower
Holder
Wall Fastener
Ensure that the minimum distance between
the hob and the extractor hood is maintained
- 400 mm for an electric hob and 550 mm
for a gas hob. 1.)
template, please ensure that the clearance
between the bottom edge of the hood
body and the bottom edge of the drilling
template is 755 mm (see Fig. drilling
template).
3. Drill 2x 6 mm ø holes for the upper fixing
bracket.
Connection
for Hose
When using the drilling
4. Hole (diameter 10mm) for the attachment
of the exhaust hood.
5. Please be certain to center the exhaust
hood over the cooking area.
6. Drill the holes and insert suitable screw
anchors flush.
7. Attach suspension (tower holder angle)
to the upper tower.
8. Screw machine screws into the screw
anchors (Ø10 mm) until they protrude by
about 20mm.
9. Hang the exhaust hood on the upper
attachment points and loosely fasten it
using the washers and nuts.
10. Align the exhaust hood (inspect the
installation) and tighten the nuts.
11. Additionally secure the exhaust hood with
two additional screws.