SDH Command Reference
SOURce subsystem - Transmitter SDH Settings Commands
:SOURce:DATA:TELecom:SDH:PRIMary:BACKground:PAYLoad
:PATTern?
:SOURce:DATA:TELecom:SDH:TUG3:BACKground:PAYLoad:PATTern
<numeric> <discrete>
Selects the structure in a background TUG3. This command is only valid if the
selected TUG3 is not the current foreground.
The corresponding query returns the specified TUG3 background structure in
discrete form as listed above.
:SOURce:DATA:TELecom:SDH:TUG3:BACKground:PAYLoad:PATTern?
<numeric>
:SOURce:DATA:TELecom:SDH:TUG3:BACKground:PAYLoad:PATTern:U
WORd <numeric> <string>
Sets the user pattern to be transmitted in the specified background TUG3. This
command is only valid if the TUG3 selected is not the current foreground.
The corresponding query returns the background word pattern in the TUG 3 selected
by numeric.
:SOURce:DATA:TELecom:SDH:TUG3:BACKground:PAYLoad:PATTern:U
WORd? <numeric>
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Returns:
<numeric> =
1 to 3
<discrete>
TU3
TU12
UWORd
<numeric> =
1 to 3
<numeric> =
1 to 3
<string>
8 bit
<numeric> =
1 to 3
<discrete>
TUG 3 to be configured
TU-3 structure
TU-12 structure
User Defined
TUG 3 to be configured
00000000 to 11111111
3-21