Theben LUNA 111 top3 AL Manual page 24

Digital twilight switch
Hide thumbs Also See for LUNA 111 top3 AL:
Table of Contents

Advertisement

6. Technical data
Operating voltage:
Frequency:
Standby:
Brightness range:
On/off switch delay:
Switching capacity max.:
Switching capacity:
Min. switching capacity:
Switch output:
Shortest switching time:
Switching accuracy:
Protection class:
Software:
Rated impulse voltage:
Pollution degree:
Contact:
Incandescent lamp load:
Halogen lamp load:
Fluorescent lamps: uncorrected:
series-corrected:
parallel-corrected:
Compact fluorescent tubes (EVG):
LED lamps (< 2 W):
LED lamps (> 2 W):
Bluetooth OBELISK top3:
– Protection rating:
– Temperature:
– Range:
Permissible ambient temperature:
110–230 V AC, +10 % / –15 %
50–60 Hz
0,8 W
1–99.000 lx
0–59 min
16 A (at 250 V, cos ϕ = 1)
10 A (at 250 V, cos ϕ = 0,6)
10 mA/230 V AC
100 mA/24 V AC/DC
Switching of any external conduc-
tor is permitted
1 s
to the second
II in accordance with EN 60730-1
subject to designated installation
class A
4 kV
2
Changeover contact
2600 W
2600 W
2600 VA
2600 VA
1300 VA (130 µF)
1100 W
50 W
600 W
IP 40
–30 °C ... +55 °C
15 m on open air test site
–25 °C ... +55 °C,
–40 °C ... +70 °C (sensor)
24

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents