Note: Carefully check if there is any damage of joints before installation.
The joints shall not be reused, unless after re-fl aring the pipe.
Tightening torque table
The size of
pipe(mm)
Ø 6,36mm(1/4")
Ø 9,52mm(3/8")
Ø 12,7mm(1/2")
Ø 15,88mm(5/8")
Ø 19,05mm(3/4")
WRAP THE PIPING
1. Use the insulation sleeve to wrap the joint
part the indoor unit and the connection
pipe,and then insulating material to pack and
seal insulation pipe,to prevent generation of
condensate water on the joint part.
2. Connect the water outlet with drain pipes,
and make the connection pipe, cables, and
the drain hose straight.
3. Use plastic cable ties to wrap the connecting pipes,cables and drain hose.
Run the pipe sloping downward.

FIXING THE INDOOR UNIT

1. Hang the indoor unit on the peg board,
and move the unit from left to right
to ensure that the hook is properly
positioned in the peg board.
2. Push toward the lower left side and the
upper right side of the unit toward the
peg board, until the hook is embedded in the slot and makes a «click»
sound.
Torque
(N • m)
15~25
35~40
45~60
73~78
75~80
80
Indoor unit pipe
Taper nut Connecting pipe
Spanner
Torque wrench
Connecting
Pipe
Drain Hose
And Cables