INSTALLATION OF INDOOR UNIT

Step 1:
Choose installation location
Recommend the installation location to the client and then confirm it
with the client.
Step 2:
Install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal
position with the level meter and then point out the screw fixing
holes on the wall.
2. Drill the screw fixing holes on the wall with impact drill(the
specification of drill head should be the same as the plastic
expansion particle) and then fill the plastic expansion particles in
the holes.
3. Fix the wall-mounting frame on the wall with tapping screws and
then check if the frame is firmly installed by pulling the frame. If the
plastic expansion particle is loose, please drill another fixing hole
nearby.
Wall
Space to the
wall above
150mm
Left
Φ55mm
Φ70mm
Step 3:
Open piping hole
1. Choose the position of piping hole according to the direction of
outlet pipe. The position of piping hole should be a little lower than
the wall-mounted frame, shown as below.
NOTE
The wall panel is for illustrative purposes only, please refer to the
actual installation.
Please refer to the actual circumstances for the number of screws
and the position of screws.
(For some models)
16
Wall
Space to the
wall above
150mm
Right
Φ55mm
Φ70mm
GB