Unit Selection: - Expert List; Factory Setting; Access Level: 2; Dynamic Index - Siemens SINAMICS S Series List Manual

Hide thumbs Also See for SINAMICS S Series:
Table of Contents

Advertisement

r0721
CU digital inputs, terminal actual value / CU DI actual value
CU_S
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the simu-
lation mode (p0795.x = 1) to terminal mode (p0795.x = 0). The input signal at terminal DI x is displayed in bit x of
r0721.
Bit field:
Bit
Signal name
00
DI 0 (X122.1/X121.1)
01
DI 1 (X122.2/X121.2)
02
DI 2 (X122.3/X121.3)
03
DI 3 (X122.4/X121.4)
04
DI 4 (X132.1)
05
DI 5 (X132.2)
06
DI 6 (X132.3)
07
DI 7 (X132.4)
08
DI/DO 8 (X122.7/X121.7)
09
DI/DO 9 (X122.8/X121.8)
10
DI/DO 10 (X122.10/X121.10)
11
DI/DO 11 (X122.11/X121.11)
12
DI/DO 12 (X132.7)
13
DI/DO 13 (X132.8)
14
DI/DO 14 (X132.10)
15
DI/DO 15 (X132.11)
Notice:
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note:
If a DI/DO is parameterized as output (p0728.x = 1), then r0721.x = 0 is displayed.
DI: Digital input
DI/DO: Bidirectional Digital Input/Output
r0721
CX digital inputs, terminal actual value / CX DI actual value
CU_CX32
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the simu-
lation mode (p0795.x = 1) to terminal mode (p0795.x = 0). The input signal at terminal DI x is displayed in bit x of
r0721.
Bit field:
Bit
Signal name
00
DI 0 (X122.1)
01
DI 1 (X122.2)
02
DI 2 (X122.3)
03
DI 3 (X122.4)
08
DI/DO 8 (X122.7)
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Calculated: -

Dynamic index: -

Units group: -
Max
-
1 signal
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
Calculated: -
Dynamic index: -
Units group: -
Max
-
1 signal
High
High
High
High
High
Parameters
List of parameters

Access level: 2

Func. diagram: 1510, 2020,
2030, 2031, 2100, 2120, 2130,
2131, 2132, 2133

Unit selection: -

Expert list: 1

Factory setting

-
0 signal
FP
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Access level: 2
Func. diagram: 2220, 2230,
2231
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
Low
-
Low
-
Low
-
Low
-
Low
-
1-225