Download Print this page

Wolf ICBCT15E Installation Instructions Manual page 12

Wolf electric cooktop installation instructions

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
W O L F
U N F R A M E D
The illustrations below provide installation
specifications for Model ICBCT30EU.
For ease of installation, 838 mm cabinets are
recommended for installation of Model
ICBCT30EU.
A Wolf 762 mm built-in single oven may be
installed below Model ICBCT30EU. For this
installation, unless you are using cabinets
deeper than 610 mm, it is recommended that
the electrical supply be placed in the base
cabinet to the right of the oven. Refer to instal-
lation instructions provided with the built-in
oven for additional specifications.
I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L I C B C T 3 0 E U
762 mm
OVERALL WIDTH
108 mm
TERMINAL BOX
Overall Dimensions
M O D E L I C B C T 3 0 E U
Overall Width
Overall Height
Overall Depth
Minimum Cabinet Depth
Minimum Height Clearance*
Cut-Out Width
Cut-Out Depth
*Minimum 159 mm clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed terminal block dimensions,
refer to the illustration on page 7.
Dimensions may vary to ± 3 mm.
12
E L E C T R I C C O O K TO P S
M O D E L I C B C T 3 0 E U
533 mm
OVERALL
DEPTH
330 mm
max
SEE COUNTERTOP
140 mm
CUT-OUT BELOW
102 mm
min
610 mm
min
762 mm
108 mm
533 mm
*Minimum clearance from both side edges and back edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
578 mm
Countertop Cut-Out
114 mm
RECESSED AREA FOR
721 mm
FLUSH MOUNT INSTALLATION ONLY
492 mm
COUNTERTOP
PROFILE
22 mm
max
8 mm
**Minimum dimension, but may be exceeded by up to 3 mm.
If Model ICBCT30EU is installed above
cabinets, electrical placement is not critical. A
grounded electrical box should be located
within 1.2 m of the right rear of the cooktop.
For Model ICBCT30EU installation options,
refer to Unframed Installations on pages
14–15.
IMPORTANT NOTE: For flush mount applica-
tions, it is recommended to measure the
cooktop glass before cutting the countertop to
ensure a proper fit. Small variances may exist
between the template and the cooktop.
838 mm
457 mm
51 mm*
min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
102 mm
914 mm
TO OVEN
STANDARD
OPENING
FLOOR TO
COUNTERTOP
HEIGHT
FLUSH MOUNT INSTALLATION ONLY
33 mm
RADIUS
537 mm**
RECESSED AREA
FOR FLUSH MOUNT
INSTALLATION ONLY
40 mm
FRONT OF COUNTERTOP
RECOMMENDED
762 mm
CABINET WIDTH
762 mm
min
COUNTERTOP TO
COMBUSTIBLE
SEE COUNTERTOP
MATERIALS
CUT-OUT BELOW
ABOVE COOKTOP
114 mm
89 mm
E
254
min
mm
762 mm OVEN OPENING
765 mm**
RECESSED AREA FOR
721 mm
COOKTOP
CUT-OUT WIDTH
51 mm*
11 mm
RADIUS
492 mm
COOKTOP
CUT-OUT DEPTH
62 mm

Advertisement

loading

This manual is also suitable for:

Icbct36euIcbct30euIcbct30eIcbct36e