Sony DCR-DVD510E Service Manual page 12

Digital video camera recorder
Hide thumbs Also See for DCR-DVD510E:
Table of Contents

Advertisement

1-4-3. Self-diagnosis Code Table
Self-diagnosis Code
Block
Detailed
Function
Code
C
0
4
0
C
1
3
0
C
1
3
0
C
3
2
6
E
2
0
0
E
3
1
0
E
6
1
1
E
6
1
1
E
6
2
0
E
6
2
0
E
6
2
0
E
6
2
0
E
6
2
1
E
6
2
1
E
6
2
1
E
6
2
2
E
9
1
0
E
9
4
0
E
9
4
0
Note 1: Refer to Service manual, ADJ ("1-3. DESTINATION DATA WRITE").
Note 2: When the lens block was replaced, execute a necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
DCR-DVD510E/DVD910/DVD910E/
HDR-UX9E/UX10/UX10E/UX19E/UX20/UX20E_L2
Symptom/State
0
Non-standard battery is used.
"Memory Stick Duo" is unformatted.
1
"Memory Stick Duo" is broken.
2
Disc access error
Difficult to adjust focus
0
(Cannot initialize focus)
0
Flash memory data are rewritten.
0
Drive fault
Zoom operations fault
0
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
1
initialization of the zoom lens occurred
simultaneously.
Handshake correction function does not
0
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
1
work well. (With YAW angular velocity
sensor output stopped.)
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
3
communication abnormality among.
0
Shift lens initializing failure.
1
Shift lens overheating (Pitch).
2
Shift lens overheating (Yaw).
0
Abnormality of thermistor.
1
Abnormality when flash is being charged.
Fault of writing to or erasing the flash
0
memory
1
Internal flash memory fault
Use the InfoLITHIUM battery.
Format the "Memory Stick Duo".
Insert a new "Memory Stick Duo".
Clean the disc with the supplied cleaning cloth.
Use a compatible disc with the camcorder.
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin qh, qj of
CN5101 on the LD-233 board). If it is OK, check the focus
motor drive IC (IC5201 on the LD-233 board).
Make flash memory data correct value. (Note 1)
Inspect or replacement of the mechanism deck, IC (IC4401 on
the VC-521 board) and drive block.
Inspect the lens block zoom MR sensor (pin ql, wa of CN5101
on the LD-233 board) when zooming is performed when the
zoom lever is operated, and the zoom motor drive circuit
(IC5201 on the LD-233 board) when zooming is not performed.
Check both C : 32 : 60 and E : 61 : 10 of the self-diagnosis code.
Inspect PITCH angular velocity sensors (SE6501 on the FR-283
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE6502 on the FR-283
board) peripheral circuits.
Refer to [1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC5501 on the LD-233 board).
Replacement of lens block. If an error occurs again, replace the
LD-233 board. (Note 2)
Refer to [1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
Refer to [1-5-4. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
Checking of flash unit or replacement of flash unit.
Inspect the flash memory (IC2101 on the VC-521 board).
Inspect the internal flash memory (MDL4060S3C). (HDR-UX19E/
UX20/UX20E only)
1-3
ENGLISH
JAPANESE
ENGLISH
JAPANESE
Correction

Advertisement

Table of Contents
loading

Table of Contents