DNP V3.0 Device Profile
2.1

Implementation Table

OBJECTS
Object Vari-
Description
ation
1
0
Binary Input -
Any Variations
1
2
Binary Input with Status
2
0
Binary Input Change -
Any Variations
2
2
Binary Input Change with Time
10
0
Binary Output -
Any Variations
10
2
Binary Output with Status
12
1
Contol Relay Output Block
20
0
Binary Counter -
Any Variations
20
1
32-Bit Binary Counter
(with Flag)
22
0
Counter Change Event -
Any Variations
22
1
32-Bit Counter Change Event
without Time
16
The following table gives a list of all objects recognized and returned by the SIPRO-
TEC device.
For static objects, requests sent with qualifiers 00, 01, 06, 07 or 08 will be responded
with qualifiers 00 or 01.
Requests sent with qualifiers 17 or 28 will be responded with qualifiers 17 or 28.
For change-event objects, qualifiers17 or 28 are always responded.
In the table below text shaded 00, 01 (start stop) indicates Subset Level 3 functionality
(beyond Subset Level 2), text shaded as 07, 08 (limited qty) indicates functionality be-
yond Subset Level 3.
1
Function Codes
(dec)
1
1
1
1
1
1
3
4
5
(direct op.)
6
(dir. op. noack)
1
1
1
1
REQUEST
Qualifier Codes
(hex)
00, 01
(read)
(start-stop)
06
(no range)
07, 08
(limited qfy)
17, 28
(index)
00, 01
(read)
(start-stop)
06
(no range)
07, 08
(limited qfy)
17, 28
(index)
06
(read)
(no range)
07, 08
(limited qfy)
(read)
06
(no range)
07, 08
(limited qfy)
00, 01
(read)
(start-stop)
06
(no range)
07, 08
(limited qfy)
17, 28
(index)
00, 01
(read)
(start-stop)
06
(no range)
07, 08
(limited qfy)
17, 28
(index)
00, 01
(select)
(start-stop)
07, 08
(operate)
(limited qfy)
17, 28
(index)
(read)
00, 01
(start-stop)
06
(no range)
07, 08
(limited qfy)
17, 28
(index)
00, 01
(read)
(start-stop)
06
(no range)
07, 08
(limited qfy)
17, 28
(index)
06
(read)
(no range)
07, 08
(limited qfy)
06
(read)
(no range)
07, 08
(limited qfy)
SIPROTEC DNP 3.0 - Bus mapping / Point lists 7SJ80/7SK80/7RW80
RESPONSE
Function Codes
Qualifier Codes
(dec)
(hex)
129
00, 01
(response)
17, 28
129
(response)
17, 28
130
(unsol. resp)
129
00, 01
(response)
17, 28
129
(response)
echo of response
C53000-L2040-A320-2
(start-stop)
(index)
(index)
(start-stop)
(index)