DV40 FL display. Press the ENTER/YES key to update the Main PCB assy (CPU Module PCB) software. The
example below indicates that there is a "V1.12" software file on the CD-ROM disk.
9. While updating, "Erase ROM" and "Write PGM" messages are displayed. After the completion with "Completed!"
message, DV40 goes back to the normal display.
10. Power off and then back on DV40.
11. Confirm each software version by SETUP mode (Main and Ether Card PCB) and special mode (Display PCB)
explained later.
3-2-2. When using DVD-RAM drive & disk
1. Using a utility software, extract a WinZip compressed software update file "DV40VXXX.zip". (XXX indicates
the software version number.) There are three files extracted as follow.
1) DV40dXXX.HEX (XXX: software version number) for Display PCB
2) dv40eXXX.mot
3) dv40mXXX.mot
2. Boot up a DVD-RAM disk formatting software, insert a blank DVD-RAM disk into an ATAPI or SCSI DVD-
RAM drive connected to a PC, format the disk by UDF1.5 and copy the above software update files to the DVD-
RAM disk. Please remember that the software update files must be placed in the 1st directory tree and not be
included in a folder.
3. After copying, take out the DVD-RAM disk with software update files from the drive.
4. Power on DV40, press the OPEN/CLOSE key to open the disk tray and put the disk into the DVD-RAM drive.
5. "Scan Disk!" and "CD" are displayed. Then, if DV40 properly finds the software update file on the DVD-RAM
disk, "V-UP Disp Yes?" will appear on the DV40 FL display. Also the software version number of the update file
is displayed.
6. Press the ENTER/YES key to update the Display PCB software. While updating the software, the FL display is
blacked out for about 1 minutes but do not power off DV40 and leave it until the next message shows up.
7. After the completion, "V-UP Ether Yes?" and the software version number of the update file will appear on the
DV40 FL display. Press the ENTER/YES key to update the Ether PCB assy software.
8. While updating, "Transfer file", "Erase..." and "Program..." are displayed. After the completion with "Completed!"
message, "V-UP Main Yes?" and the software version number of the update file will appear on the DV40 FL
display. Press the ENTER/YES key to update the Main PCB assy (CPU Module PCB) software.
9. While updating, "Erase ROM" and "Write PGM" are displayed. After the completion with "Completed!" message,
DV40 goes back to the normal display.
10. Power off and then back on DV40.
11. Confirm each software version by SETUP mode (Main and Ether Card PCB) and special mode (Display PCB)
explained later.
[NOTE]
Instead of using the DVD-RAM drive connected to a PC, the DVD-RAM disk can be formatted using the Format menu
in the DV40 Utility mode ([SHIFT] + [SETUP]). In such a case, regardless of Normal or Tape formatting mode, simply
format the disk. The important thing is to place the software files in the 1st directory tree.
[CAUTION]
1. Please make sure to power off and then back on DV40 and initialize it (See page 14.) after updating the software.
2. When using a DVD-RAM disk for updating the software, please make sure to format it by UDF1.5. If the disk is
formatted by UDF2.0, it might not be correctly recognized by a Macintosh computer.
3. Please remember that all three software files are not necessarily sent to you every time. For example, there is a
case that only the software for Main PCB (CPU Module PCB) and Ether Card PCB are sent to you.
1
2
60
50
42
34
28
2018
12
3
4
(XXX: software version number) for Ether PCB
(XXX: software version number) for Main PCB (CPU Module PCB)
BIT
24
FS
48
kHz
CLOCK
-0.1%
8
6 5 4 3 2 1 0 OL
-INT-
FORMAT
BWF
Service Manual
11