  • Page 1 ® INSTRUCTION MANUAL ® Evolv Upper Arm Blood Pressure Monitor Model BP7000...
  • Page 2 INTRODUCTION Thank you for purchasing the OMRON BP7000 Blood Pressure Monitor. Your new blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INTENDED USE...................4 IMPORTANT SAFETY INFORMATION ............5 1. KNOW YOUR MONITOR ..............8 2. PREPARATION ...................12 3. USING THE MONITOR WITHOUT A SMART DEVICE ......16 4. USING THE MONITOR WITH A SMART DEVICE......18 5. ERROR MESSAGES AND TROUBLESHOOTING ......25 6.
  • Page 4: Intended Use

    INTENDED USE This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population with arm circumference ranging from 9 inches to 17 inches (22 cm to 42 cm). The device detects the appearance of irregular heartbeats during measurement and gives a warning signal with readings.
  • Page 5: Important Safety Information

    IMPORTANT SAFETY INFORMATION Please read the Important Safety Information in this instruction manual before using the unit. Please follow this instruction manual thoroughly for your safety. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR PHYSICIAN. Contraindications •...
  • Page 6 IMPORTANT SAFETY INFORMATION • This product emits radio frequencies (RF) in the 2.4 GHz band. DO NOT use this product in locations where RF is restricted, such as on an aircraft or in hospitals. For further information on any potential restrictions refer to documentation on ®...
  • Page 7 IMPORTANT SAFETY INFORMATION • Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for 30 minutes before taking a measurement. • Rest for at least 5 minutes before taking the measurement. • Remove tight-fitting or thick clothing from your arm while taking a measurement. •...
  • Page 8: Know Your Monitor

    1. KNOW YOUR MONITOR Contents: Monitor, 4 “AAA” batteries, instruction manual, quick start guide Monitor: A. START/STOP button B. Connection button C. Display D. Arm cuff E. Battery compartment Display: F. Systolic blood pressure G. Diastolic blood pressure H. Pulse display...
  • Page 9 1. KNOW YOUR MONITOR Connection symbol Irregular heartbeat symbol Connection OFF symbol Battery symbol (low) Connection ON symbol Battery symbol (depleted) Movement error symbol Deflation symbol Heartbeat symbol SYNC symbol (Flashes during measurement.) 1.1 Display symbols Connection symbol ( Appears when transferring the data or pairing with your smart device. Connection OFF symbol ( Appears when Bluetooth is off.
  • Page 10 1. KNOW YOUR MONITOR Irregular heartbeat symbol ( When the monitor detects an irregular rhythm two Normal Heartbeat or more times during the measurement, the Pulse irregular heartbeat symbol will appear on the Blood pressure display along with the measurement values. An irregular heartbeat rhythm is defined as a Irregular Heartbeat rhythm that is 25% less or 25% more than the...
  • Page 11 1. KNOW YOUR MONITOR 1.2 Classification of BP (Blood Pressure) ACC/AHA 2017 Hypertension guidelines defines categories of BP in adults as below. Categories of BP in Adults* BP Category Systolic BP Diastolic BP Normal <120 mmHg <80 mmHg Elevated 120 - 129 mmHg <80 mmHg Hypertension Stage 1...
  • Page 12: Preparation

    2. PREPARATION 2.1 Battery Installation Remove the battery cover. Insert your fingernail into the slot of the battery cover, and push downwards to remove the cover. Insert battery, slide over so it is secured inside the circular battery positioner. Then insert the second battery.
  • Page 13 2. PREPARATION Replace the battery cover. When the batteries have been securely placed in this monitor, the message below will appear on the screen: Notes: • When the depleted battery symbol “ ” appears on the display, turn the monitor off and remove all the batteries. Replace with 4 new batteries at the same time.
  • Page 14 Omron recommends to always use the same arm for measurement. If the values between both arms differ substantially, please check with your physician as to which arm to use for your measurements.
  • Page 15 2. PREPARATION 2.3 How to Sit Correctly To take a measurement, you need to be relaxed and comfortably seated, at a comfortable room temperature. • Sit in a chair with your legs uncrossed and your feet flat on the floor. •...
  • Page 16: Using The Monitor Without A Smart Device

    3. USING THE MONITOR WITHOUT A SMART DEVICE You can use this blood pressure monitor without pairing to a smart device. 3.1 Taking a Measurement Notes: • To stop the measurement, press the [START/STOP] button once to deflate the arm cuff. •...
  • Page 17 3. USING THE MONITOR WITHOUT A SMART DEVICE Write down your SYS/DIA and Pulse readings, along with the date and time of your measurement on a piece of paper to keep a record of your history. DO NOT adjust medication based on measurement results from this blood pressure monitor.
  • Page 18: Using The Monitor With A Smart Device

    Download and install the free “OMRON connect US/CAN” app on your smart device. * If you already have the “OMRON connect US/CAN” app, and have created your account, open the app and add your new monitor. Open the app on your smart device and follow the set-up and pairing instructions.
  • Page 19 • The date/time will only be set for future measurements taken after the measurement that was transferred. It will not be saved to the measurement that was just transferred. • Please be aware that OMRON will not be responsible for the loss of data and/or information.
  • Page 20 • Remain still and do not talk while taking a measurement. • This monitor will store 100 measurements. Stored measurements cannot be viewed on the monitor's display. You will need to use the “OMRON connect US/CAN” app to view all measurements prior to the most recent reading taken.
  • Page 21 Transfer your readings. Make sure your monitor is within 16 ft. (5 m) of your smart device. As soon as your measurement is complete, open the OMRON connect US/ CAN app on your smart device to transfer your readings. your readings later Transferring 1.
  • Page 22 • If you use any other app instead of “OMRON connect US/CAN”, the data may not be displayed correctly after sending. DO NOT adjust medication based on measurement results from this blood pressure monitor.
  • Page 23 4. USING THE MONITOR WITH A SMART DEVICE ® 4.3 Turning “OFF” Bluetooth ® Turn off the Bluetooth in your monitor in the following areas where use of wireless equipment is prohibited. • On aircraft • In hospitals • While abroad ®...
  • Page 24 4. USING THE MONITOR WITH A SMART DEVICE 4.4 Restoring Your Monitor to the Default Settings To delete all the information stored in your monitor, follow the instructions below. Make sure that your monitor is turned off. It will be off when the screen is not showing numbers or symbols.
  • Page 25: Error Messages And Troubleshooting

    5. ERROR MESSAGES AND TROUBLESHOOTING 5.1 Error Messages Error Display Cause Solution Remove the arm cuff. Wait 2 - 3 minutes and then take another measurement. Irregular heartbeat is Repeat the steps in detected. section 2.2. If this error continues to appear, contact your physician.
  • Page 26 5. ERROR MESSAGES AND TROUBLESHOOTING Error Display Cause Solution The arm cuff was inflated exceeding the Do not touch the arm cuff maximum allowable while taking a measurement. pressure, and then Refer to section 3.1 or 4.2. deflated automatically. Repeat measurement. Movement during Remain still and do not talk measurement.
  • Page 27 5. ERROR MESSAGES AND TROUBLESHOOTING 5.2 Troubleshooting Problem Cause and Solution Replace all batteries with new ones. No power. Check the battery installation for proper No display appears on the placement of the battery polarities. monitor. Refer to section 2.1. Blood pressure varies constantly.
  • Page 28 5. ERROR MESSAGES AND TROUBLESHOOTING Problem Cause and Solution The blood pressure monitor might not be properly placed within the smart device's transmission range and is too far from the smart device. If there are no causes of data transmission interference found near the blood pressure monitor, move the blood pressure monitor within 16 ft.
  • Page 29: Maintenance, Storage And Cleaning

    6. MAINTENANCE, STORAGE AND CLEANING 6.1 Maintenance To protect your monitor from damage, please follow the directions below: • Store the monitor and the components in a clean, safe location. • Do not wash the monitor and any components or immerse them in water. •...
  • Page 30: Disposal

    7. DISPOSAL Dispose of the monitor and components according to applicable local regulations. Unlawful disposal may cause environmental pollution.
  • Page 31: Specifications

    8. SPECIFICATIONS Model BP7000 HEM-7600T-Z Display OLED display Cuff pressure range Pressure: 0 to 299 mmHg Measurement range Pressure: 40 to 260 mmHg Pulse: 40 to 180 beats / min. Accuracy Pressure: ±3 mmHg Pulse: ±5% of display reading Inflation Fuzzy-logic controlled by electric pump Deflation Automatic rapid deflation...
  • Page 32 8. SPECIFICATIONS Notes: • These specifications are subject to change without notice. • In the clinical validation study, K5 was used on 85 subjects for determination of diastolic blood pressure. • This monitor is clinically investigated according to the requirements of ISO 81060-2:2013.
  • Page 33: Fcc Statement

    9. FCC STATEMENT FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 34: Limited Warranty

    The above warranty extends only to the original retail purchaser, and only to products purchased from an Omron authorized seller who is subject to and follows Omron’s quality control standards, unless otherwise prohibited by law.
  • Page 35: Guidance And Manufacturer's Declaration

    Nevertheless, special precautions need to be observed: • The use of accessories and cables other than those specified by OMRON, with the exception of cables sold by OMRON as replacement parts for internal components, may result in increased emission or decreased immunity of the device.
  • Page 36 Guidance and manufacturer’s declaration - electromagnetic emissions OMRON battery-operated BPM is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON battery-operated BPM should assure that it is used in such environment. Emissions test...
  • Page 37 Guidance and manufacturer’s declaration - electromagnetic immunity OMRON battery-operated BPM is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON battery-operated BPM should assure that it is used in such environment. Electromagnetic environment -...
  • Page 38 Guidance and manufacturer’s declaration - electromagnetic immunity OMRON battery-operated BPM is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON battery-operated BPM should assure that it is used in such environment. IEC 60601...
  • Page 39 OMRON battery-operated BPM OMRON battery-operated BPM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of this OMRON battery-operated BPM can help prevent electromagnetic interference by maintaining a minimum distance between...
  • Page 40 The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by OMRON HEALTHCARE Co., Ltd. is under license. Other trademarks and trade names are those of their respective owners. Apple and the Apple logo, are trademarks of Apple Inc., registered in the U.S. and other countries and regions.