Test Mode Activation; Erasing Operating Parameters - Metra Electronics ELS NET LC16ANT Technical Manual

Locker controller
Table of Contents

Advertisement

 Test mode activation
STEP 2:
Connect the ELS NET Tester to the Locker Controller as described in the paragraph "ELS NET
Tester connection".
STEP 3:
Power-off and back on the Locker Controller to activate the Test mode.
NOTE:
To return to Normal mode of operation set the switches 1 to 4 back to OFF (switch down) and
power-off and back on the Locker Controller.
 Erasing operating parameters
Operating parameters can be erased (initialized to default values) only in Test mode of operation.
Locker Controller ELS NET Technical Manual
STEP 1:
With small flat headed screwdriver or similar tool
set switches 1 to 4 located on the "Operating mode DIP
switch" to ON (switch up).
STEP 4:
Shortly after power on, numbers from "0.0.0.0."
to "9.9.9.9." are displayed. This indicates that the Test
mode of operation is activated.
STEP 1:
Before powering-up the Locker Controller in Test
mode,
both
pushbuttons
Parameters request) should be pressed and hold for 3
seconds after power up.
Operating parameters are erased.
Upon buttons release, Test mode of operation is
activated.
Page 18