INSTALLATION OUTDOOR

18. OUTDOOR UNIT INSTALLATION

18.1 Installation place
Please keep away from the following locations, or malfunction of the machine may be caused:
There is combustible gas leakage.
There is much oil (including engine oil) ingredient.
There is salty air surrounding(near the coast)
There is caustic gas (sulfide, for example) existing in the air.
A place the heat air expelled out from the outdoor unit can reach your neighbour's window.
A place that the noise interferes your neighbours.
A place that is too weak to bear the weight of the unit
Uneven place.
Insufficient ventilation place.
Near a private power station or high frequency equipment.
Install indoor unit, outdoor unit, power cord and connecting wire at least 1m away from TV set or radio to
prevent noise or picture interference.
The insulation of the metal parts of the building and the air conditioner should comply with the regulation of
National Electric Standard.
Keep indoor unit, outdoor unit, power supply wiring and transmission wiring at least 1 meter away
from televisions and radios. This is to prevent image interference and noise in those electrical
appliances. (Noise may be generated depending on the conditions under which the electric wave
CAUTION
is generated, even if 1 meter is kept.)
18.2 Installation space (Unit:mm)
1120
Figure 33.
Rinnai
(Wall or obstacle)
Air inlet
>300
Air inlet
36
668
206
Service access
>600
Air outlet
Single unit installation
Ducted Reverse Cycle Inverter Installation Manual