Fig. 138: Measuring Resistance Between Terminals +B And HT Using Ohmmeter
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
If the resistance is not as specified, replace the sensor.
Torque: 44 N.m (450 kgf.cm, 32 ft.lbf)
c. Reconnect the sensor connector.
2. INSPECT OPERATION OF HEATED OXYGEN SENSOR (See DTC P0136: OXYGEN SENSOR
CIRCUIT MALFUNCTION (BANK 1 SENSOR 2) )
ACCELERATOR PEDAL POSITION SENSOR
COMPONENTS
2004 Toyota RAV4
2004 ENGINE PERFORMANCE SFI - RAV4