en | Configuration through the Web Interface
5

Configuration through the Web Interface

NOTICE!
i
Do not use the S5B50 management software StoreVault Manager for the configuration. The
DSA series come with a dedicated Bosch standardized system layout. StoreVault Manager is
not compatible with the Bosch layout.
Follow these steps to configure each system. This procedure is nearly identical for all three
types of storage systems.
1.
NOTICE!
i
It can take a few seconds until the LEDs on your system power supplies light up.
NOTICE!
i
The Java Runtime Environment must be installed on your computer in order to use the Web
interface. Always use the most recent version.
5.1
Configuration of the Network Settings and Access to the
Interface
All systems are delivered with a default IP address configuration of 10.10.10.10, netmask
255.0.0.0. In order to connect to the system, you need to configure a network interface on
your computer to use the same network.
V 1 | 2008.08
Turn on the system.
DSA-S5B50: The power button is located on the front side on the left-hand side.
DSA-N2B20 / DSA- N2B50 / additional disk shelves: There is a power switch on each
power supply unit (right- and left-hand side) on the rear side of the device.
If there are additional disk shelves installed, first power on the base unit, then power on
the expansion units.