Installing the air conditioner
Pressure table for temperatures
If you need extra refrigerant charging due to leakage or relocating the product, refer to below table before charging
refrigerant.
❋ ❋ Cooling operation
Indoor temperature (°C)
(Dry bulb / Wet bulb)
Outdoor temperature(°C)
52
35
21
7
-15
❋ ❋ Heating operation
Indoor temperature (°C)
(Dry bulb / Wet bulb)
Outdoor temperature(°C)
24
7
-5
-20
❋ ❋ Pressure for each temperature was measured at gas side service valve.
PAC MIRAGE Saudi_IBIM_EN_CS6_DB68-04872A-05.indd 58
32/23
27/19
1110
900
920
750
830
690
690
540
550
400
27/15
20/15
3630
3400
2840
2670
2650
2470
2060
1890
ENGLISH-58
Unit : [kPa, G]
21/15
780
640
590
490
370
Unit : [kPa, G]
13/10
3100
2400
2200
1620
2016-08-08 오전 11:38:40