Samsung AF55JV MA N Series User & Installation Manual page 53

Table of Contents

Advertisement

Installing the air conditioner
How to connect your extended power cables
1. Prepare the following tools.
Tools
Spec
Shape
2. As shown in the figure, peel off the shields from the rubber and wire of the
power cable.
- Peel off 20 mm of cable shields from the pre-installed tube.
• For information about the power cable specifications for
indoor and outdoor units, refer to the installation manual.
CAUTION
• After peeling off cable wires from the pre-installed tube, insert
a contraction tube.
3. Insert both sides of core wire of the power cable into the connection sleeve.
f Method 1
f
Push the core wire in to the sleeve from both sides.
f Method 2
f
Twist the wire cores together and push it in to the sleeve.
PAC MIRAGE Saudi_IBIM_EN_CS6_DB68-04872A-05.indd 53
Crimping pliers
Connection sleeve (mm)
MH-14
20xØ6.5(HxOD)
ENGLISH-53
Insulation tape
Contraction tube (mm)
Width 19 mm
70xØ8.0 (LxOD)
Power cable
20
20
120
180
20
Pre-installed tube for the power cable
Connection sleeve
Connection sleeve
2016-08-08 오전 11:38:37
20
60
(Unit: mm)