Page 1
USER MANUAL HYSC-7000 BATTERY CHARGER HYSC-7000 Please read and understand all important safety and operating instructions before using this charger. In addition, please read and follow all battery and vehicle manufacturer’s instructions and cautionary markings.
Page 2
HYSC-7000 We are still constantly improving this smart battery charger, therefore, some parts of this smart battery charger may be changed in order to achieve the better quality, but the main functions and operations will not be alternated and changed. Your understanding would be greatly appreciated.
HYUNDAI Table of Contents SAFETY CONNECTING TO THE BATTERY ABOUT HYSC-7000 CHARGING MODES CHARGING STEPS BATTERY CHARGING LEVEL INDICATOR CHARGING TIME LED MESSAGES...
HYSC-7000 1. SAFETY SAFETY PRECAUTIONS FOR WORKING IN THE VICINITY OF A BATTERY 1) Batteries generate explosive gases during normal operation. Use in well-ventilated area. 2) Consider having someone close enough or within the range of your voice to come to your aid when you work near a battery.
HYUNDAI 7) To reduce the risk of damage to electric plug and cord, pull by the plug rather than the cord when disconnecting charger. 8) To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or cleaning.
HYSC-7000 3. ABOUT HYSC-7000 1) The HYSC-7000 is designed for charging all types of 12V lead-acid ,24V lead-acid and 12V lithium-ion batteries, including WET (Flooded), GEL, MF (Maintenance-Free), EFB (Enhanced Flooded Battery), AGM (Absorbed Glass Mat),AGM+ (Absorbed Glass Mat+) and LIB (Lithium Ion) batteries.
HYUNDAI 4. CHARGING MODES HYSC-7000 has nine modes: Standby, 12V NORM, 12V COLD/AGM, 24V NORM, 24V COLD/AGM, 12V AGM+, 12V LITHIUM, 12V/24V REPAIR and 13.6V SUPPLY. Some charge modes must be pressed for three (3) seconds or / and pressed to enter the mode. Do not operate the charger until you confirm the appropriate charge mode for your battery.
Page 10
HYSC-7000 Using 12V AGM+ This mode is designed for 12V advanced AGM batteries only. Advanced AGM batteries are typically found in startstop micro-hybrid vehicles. These batteries accept a higher than normal charging voltage. 12V AGM+ charge mode is NOT suitable for traditional AGM batteries. Consult the battery manufacturer before using this mode.
HYUNDAI 5. CHARGING STEPS Step Voltage(V) Current(A) STEP 1: DIAGNOSIS (Check if battery has connected with the charger and also check battery voltage) STEP 2: DESULPHATION (If battery voltage is too low, programs automatically generate pulsing current to remove sulphate, up to 5 hours)
HYSC-7000 6. BATTERY CHARGING LEVEL INDICATOR Explanation The 25% Charge Red LED will slowly flash when the battery level is less than 25%. When 25% is reached, the LED will be solid. The 50% Charge Red LED will slowly flash when the battery level is less than 50%.
HYUNDAI 8. LED MESSAGES LIGHT(S) CONDITION CAUSE(S) SOLUTION(S) Exchange the red and black Solid Red Warning! LED Reverse Polarity clamps or ring terminals to the correct battery posts 1) Connect the red and black clamps or ring terminals to the...
Page 14
HYSC-7000 Flashing Yellow Warning! LED Heavily Corroded Battery Replace with a new battery or try (for both 12V and 24 lead-acid (voltage is less than 3V) REPAIR Mode for recovery batteries.) NOTICE: following situation indicates that battery need to be replaced, although there is no abnormal result LED communication.
Page 15
HYUNDAI Corporation 25, Yulgok-ro 2-gil, Jongno-gu, Seoul 03143 Korea Declare that the product detailed below : BATTERY CHARGER FOR LEAD ACCUMULATOR MODEL : HYSC-7000 Satisfies the requirements of the Council Directives : EMC directive 2014/30/EU Low Voltage Directive 2014/35/EU RoHS Directive 2011/65/EU...
Page 16
HYUNDAI Corporation 25, Yulgok-ro 2-gil, Jongno-gu, Seoul 03143, Korea, Post Code : 03143 82 2 390 1114 www.hyundaicorp.com Copyright HYUNDAI Corporation All rights reserved. Made in P.R.C...