Siemens xTronic HG241 5UC Instructions Manual page 8

Gas convection range lp conversion kit
Table of Contents

Advertisement

Available languages

Available languages

10. Adjust Broil Burner Air Shutter (if nec-
essary)
Adjust Air Shutter. The air shutter is located on the back
end of the broil burner. Loosen screw and turn shutter.
Close the shutter if the flame is lifting or blowing or not
carrying over; Open the shutter if it is too yellow. (See
Figure 8). Tighten screw.
More Open:
•Less Yellow Flame
More Closed:
•Less Blue Flame
•More Carryover
•Less lifting or blowing
Figure 8 - Broil Burner Air Shutter
11. Adjust Oven Burner Air Shutter (if
necessary)
Adjust Air Shutter. The oven burner air shutter is
located to the left of the oven regulator. Reach it through
the access hole in the interior back panel of the warming
drawer. Loosen screw on shutter. Close the shutter if the
flame is lifting or blowing or not carrying over; Open the
shutter if it is too yellow. Tighten screw. (See Figure 9).
Reattach cover plate and replace warming drawer.
Shutter
More Open:
•Less Yellow Flame
Figure 9 - Oven Orifice and Air Shutter
Conversion Instructions - Test the Conversion
Shutter Screw
More Closed:
•Less Blue Flame
•More Carryover
•Less lifting or
blowing
Save natural gas orifices for future conversion by placing
them in the appropriate space below.
Natural Gas
Cooktop Orifice Placement
Left Rear Burner - 12,500
BTU/ h 165
BACK OF RANGE
FRONT OF RANGE
Left Front Burner -
9,100 BTU/h 139
Right Rear Burner -
5,500 BTU/ h 109
Right Front Burner -
15,000 BTU/h 180

Advertisement

Table of Contents