4. Convert Cooktop Valves for Propane Use
Adjust Bypass Jets on Valves
1. Verify that all knobs are in the "Off" position.
2. Remove knobs, springs and bezels by pulling straight
out on the bezel.
3. Insert 1/8" (or smaller) flat head screwdriver into
shaft and turn bypass screw clockwise until it stops
turning (bypass screw is inside shaft). See Figure 4.
DO NOT OVER TIGHTEN. Replace springs, bezels and
knobs.
Burner
Cooktop - Left Rear
Cooktop - Right Rear
Cooktop - Left Front
Cooktop - Right Front
Oven - Broil (Gas Ranges Only)
Oven - Bake (Gas Ranges Only)
If your range is dual fuel your conversion is complete.
Replace the cover plate and warming drawer and
proceed to step 9 to test your conversion.
For gas range conversions, continue to step 5, next
page.
Conversion Instructions - Cooktop
Bypass Screw Inside Shaft
BTU/h - LP Gas
Figure 4 - Cooktop Valve
11,000
5,000
7,500
15,000
13,500
17,000
1/8" (or Smaller) Flathead Screwdriver