Bunn ITB Technical Training Manual page 24

Table of Contents

Advertisement

Additional Resource
Continuity Check the Following Components
• Limit Thermostat
• Switch Membrane
Voltage Check the Following Components
• Dual Inlet Valve 120VAC
• Tank Heater 120VAC
• Stepdown Transformer 120VAC/12VAC
• Brew Valve 155VDC-non activated, 1.0VDC Activated
• Thermistor Voltage Range 1.0 – 5.0VDC Dependent Upon Temp/Resistance
Resistance Check the Following Components
• Tank Heater 8.6 Ohms and Infinite to Ground/Chasis
• Thermistor- 32º F. at 32651 Ohms, 70º F. at 11864 Ohms and 205º F. at 761 Ohms
• Dual Valve/Coils 1130 Ohms
Transformer supplies the low 12VAC to power the main control board
Primary Side: Black and White (wires)120VAC
Secondary Side: Yellow (wires) 12VAC
24
ITB Training Manual