Single package rooftop cooling only with puron (r-410a) refrigerant
Hide thumbs Also See for WeatherMaker 50TC07 Series:
Table of Contents

Advertisement

Position:
Example:
Unit Heat Type
50 - Electric Heat Packaged Rooftop
Model Series - WeatherMaker
®
TC - Standard Efficiency
Heat Size
- = No heat
Refrig. Systems Options
A = Standard One Stage Cooling Models
B = Standard One Stage Cooling with
®
Humidi-MiZer
System (07 models only)
D = Two-Stage cooling (models 08-16 only)
E = Two Stage cooling (models 08-16) with Al/Cu
Condenser Coils and Humidi-MiZer
M = Single Circuit, two stage cooling models
(08, 09, 12 models only) (Humidi-MiZer
Cooling Tons
07 = 6 tons
12 = 10 tons
08 = 7.5 tons
14 = 12.5 tons
09 = 8.5 tons
16 = 15 tons
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
Sensor
2
F = RA Smoke Detector and CO
Sensor
2
G = SA Smoke Detector and CO
Sensor
2
H = RA + SA Smoke Detector and CO
J = Condensate Overflow Switch
K = Condensate Overflow Switch and RA Smoke Detectors
L = Condensate Overflow Switch and RA and SA Smoke Detectors
Indoor Fan Options
1 = Standard Static Option
2 = Medium Static Option
3 = High Static Option
C = High Static Option with High Efficiency Motor (size 16 only)
Coil Options – RTPF (Outdoor – Indoor – Hail Guard)
A = Al/Cu – Al/Cu
B = Precoat Al/Cu – Al/Cu
C = E-coat Al/Cu – Al/Cu
D = E-coat Al/Cu – E-coat Al/Cu
E = Cu/Cu – Al/Cu
F = Cu/Cu – Cu/Cu
M = Al/Cu – Al/Cu – Louvered Hail Guard
N = Precoat Al/Cu – Al/Cu – Louvered Hail Guard
P = E-coat Al/Cu – Al/Cu – Louvered Hail Guard
Q = E-coat Al/Cu – E-coat Al/Cu – Louvered Hail Guard
R = Cu/Cu – Al/Cu – Louvered Hail Guard
S = Cu/Cu – Cu/Cu – Louvered Hail Guard
Coil Options – Novation (Outdoor – Indoor – Hail Guard)
G = Al/Al – Al/Cu
H = Al/Al – Cu/Cu
J = Al/Al – E-coat Al/Cu
K = E-coat Al/Al – Al/Cu
L = E-coat Al/Al – E-coat Al/Cu
T = Al/Al – Al/Cu – Louvered Hail Guard
U = Al/Al – Cu/Cu – Louvered Hail Guard
V = Al/Al – E-coat Al/Cu – Louvered Hail Guard
W = E-coat Al/Al – Al/Cu – Louvered Hail Guard
X = E-coat Al/Al – E-coat Al/Cu – Louvered Hail Guard
Fig. 1 — 50TC 07-16 Model Number Nomenclature (Example)
1
2
3
4
5
6
7
8
5
0
T
C
-
A
0
7
®
®
not available)
Sensor
2
9 10 11 12 13 14 15 16 17 18
A
1
A
5
-
0
A
0
A
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels and
5 = Hinged Panels and
Intake / Exhaust Options
A = None
B = Temperature Economizer w/ Barometric Relief
F = Enthalpy Economizer w/ Barometric Relief
K = 2-Position Damper
U = Temperature Ultra Low Leak Economizer
w/ Barometric Relief
W = Enthalpy Ultra Low Leak Economizer
w/ Barometric Relief
Base Unit Controls
0 = Electro-mechanical Controls can be used with W7212
EconoMi$er
1 = PremierLink
2 = RTU Open Multi-Protocol Controller
6 = Electro-mechanical w/ 2-Speed Fan and W7220
Economizer Controller Controls. Can be used with
W7220 EconoMi$er X (w/ Fault Detection & Diagnostic)
Design Revision
- = Factory Design Revision
Voltage
1 = 575/3/60
5 = 208-230/3/60
6 = 460/3/60
NOTE: Not all possible options are displayed, see the current
50TC 07-16 Price Pages for more details.
3
0
Packaging & Seismic Compliance
0 = Standard
1 = LTL
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-The-Base Connections
F = Non-Fused Disconnect and
Thru-The-Base Connections
G = 2-Speed Indoor Fan (VFD) Controller
J = 2 Speed Fan Controller (VFD) and
Non-Fused Disconnect
K = 2 Speed Fan Controller (VFD) and
Thru-The-Base Connections
M = 2 Speed Fan Controller (VFD)
with Non-Fused Disconnect and
Thru-The-Base Connections
Unpowered Convenience Outlet
Powered Convenience Outlet
®
IV (Non-Fault Detection and Diagnostic)
TM
Controller