Technical Data; Braking Resistors For Braking Modules; Installation Of The Braking Resistors - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

7.1.6

Technical data

Table 7- 4
Technical data
Braking Module Booksize
Voltages
Infeed:
DC link voltage
ON threshold
Electronics power supply
Electronics current consumption
(at 24 V DC)
Current carrying capacity
DC link busbar
Current carrying capacity
24 V busbar
Max. braking power
Continuous braking power
Power loss
1
Cooling method
Weight
1) For an overview, see the power loss tables in chapter Control cabinet installation
7.1.7

Braking resistors for Braking Modules

7.1.7.1

Installation of the braking resistors

Ideally, external braking resistors should be installed outside of the control cabinet to prevent
the heat lost by the resistors from subjecting the cabinet to thermal stress.
The resistor may be installed inside the control cabinet either standing on the cabinet floor or
suspended (horizontally or vertically) from the cabinet wall. You must ensure that the braking
resistors do not obstruct the flow of cooling air to the drive line-up.
The braking resistor can become very hot. Consequently, it must be installed so that it
cannot be touched or, if this is not possible, an appropriate warning notice must be
attached to it.
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
V
DC
V
V
DC
A
DC
A
DC
A
DC
kW
kW
W
kg
CAUTION
DC link components
7.1 Braking Module
510 - 720
770
24 (20.4 – 28.8)
0.5
100
20
100
1.5
20
Natural convection
4.1
153