Electrical System Operates Incorrectly - Ferris Voyager FS5250 Series Operator's Manual

Ride-on spreader sprayer
Table of Contents

Advertisement

FAILURE MODE

Electrical System Operates Incorrectly

FAILURE MODE
Electrical system does not operate or
operates incorrectly.
36
CAUSE OF PROBLEM
The strainer or tip is clogged.
The filter is clogged.
The pump won't operate.
Hoses are kinked.
Spray tank volume is low. 
The engine speed is too low.
The pump is worn or damaged.
CAUSE OF PROBLEM
Battery terminals require cleaning.
Battery discharged or dead.
Wiring loose or broken. 
Electrical wiring damage. 
Spark plug(s) faulty, fouled, or incorrectly
gapped.
Fuse blown. 
CORRECTIVE ACTION
Remove the spray nozzle tip. Inspect the
tip orifice and the strainer to ensure they
are not clogged. Clean or replace these
components as necessary.
Remove the sediment from the filter
housing and inspect the filter screen.
Clean or replace the screen as
necessary.
Inspect the pump fuse located in the fuse
box. Ensure that either the spray pump
ON/OFF console switch activates the
pump.
Smooth out hoses and use wire ties to
make sure that they do not kink again.
Refill the spray tank. Note that in very
rough or hilly conditions, the liquid in the
spray tanks may slosh around and the
tank discharge tube may starve when
the tank level is low. This can cause poor
spraying performance.
Operate the machine at full engine
speed. The spray system is designed
to operate most efficiently at full engine
speed.
Replace the pump.
CORRECTIVE ACTION
Clean the battery terminals. 
Recharge or replace battery.
Visually check wiring and replace
broken or frayed wires. Tighten loose
connections.
Locate and repair damaged wire.
Clean and gap or replace. See
authorized service dealer.
Replace fuse.
ferrismowers.com