Pressure Relief Procedure; Install An Agitator Onto A Non-Agitated Tank - Graco 236661 Instructions Manual

Agitators
Table of Contents

Advertisement

Installation

Pressure Relief Procedure

Follow the Pressure Relief Procedure
whenever you see this symbol.
To reduce the risk of serious bodily injury, including
splashing in the eyes or on the skin, or injury from
moving parts, which can result if the tank pressure is
not fully relieved, always follow this procedure before
opening the pressure tank cover or fill port.
1. Shut off the air supply to the tank by closing the air
inlet valve (A).
2. Turn the drain cock fitting (B) counterclockwise to
open it.
NOTE: Wait until there is no air escaping through the
fitting before removing the cover or opening the fill port.
3. Leave the drain cock fitting (B) open until the cover
or filler cap have been reinstalled.
F
. 3 5 Gallon Tank with Heavy-Duty Agitator
IG
6
Install an Agitator onto a
Non-Agitated Tank
1. Follow the Pressure Relief Procedure. Remove
the tank cover from the tank.
2. Unscrew and remove the hex jam nut (C), plug (D),
and O-ring (E) from the tank cover.
3. Place the gasket (17) on top of the tank cover center
hole. Insert the agitator drive shaft (14) through the
center hole.
NOTE: Position the air motor so it faces away from the
air regulator mounting as shown in F
4. Install the jam nut (C) below the tank cover. Tighten
the jam nut firmly to assure a seal between the
gasket (17) and tank cover.
5. Install the shaft support (11) onto the shaft housing
(9). Secure with U-bolt (26), clamp (10), lock washer
(36) and nut (25).
6. Tighten the U-bolt in a position leaving a 0.015 in.
(0.006 mm) clearance gap between the thrust
washer and the top of the shaft support. See Parts
on page 15.
14
17
D
E
C
14 (REF)
10
36
25
. 3.
IG
9
F
26
11
03261B
308371R