May.2002
When using USB
Necessary items
· SD-80 and AC power cord
· Computer equipped with a USB terminal (OS: Windows98/Me/2000)
· USB cable
· Applications to replay the SMF (recommended: Windows MediaPlayer)
· SD-80 Version Updating Disk (#17041156)
UPDATING PROCEDURE
*
Install the USB driver as instructed in "DATA SAVING AND LOADING/
PREPARATIONS FOR USING THE COMPUTER"
*
The procedure assumes that Windows MediaPlayer is used for SMF replay.
*
Updating may not be done properly if an application other than Windows
MediaPlayer is used.
*
Do not turn off the SD-80's power while applications using the SD-80 are open.
Otherwise, computer operation becomes unstable.
Close all applications being used on the SD-80 before turning off the unit's
power.
1.
While holding down the [SYSTEM], [PAGE <] and [PREVIEW] buttons,
turn on the power. The "Program Updater" message appears. Keep
holding down these buttons until the next screen appears.
fig.2-1_65
2.
Press the [PART>] button to open the "Update by USB" screen.
fig.2-1a_65
3.
Start the Windows MediaPlayer, and open the updating SMF
"f00001.mid" for USB on the SD-80 Version Updating Disk.
4.
Press the [ENTER] button. The "Waiting ..." message appears, indicating
that the unit is waiting to receive MIDI data.
fig.2-2_65
5.
Updating starts when the computer replays the SMF for updating. The
screen shows the progress during updating. The screen shows "Receiving
..." during SMF replaying to indicate that the SD-80 is in receiving mode.
fig.2-3_65
Do not turn off the power of the SD-80 during updating.
If the power is turned off, the board memories may be destroyed.
Note that the main board must be replaced in this case.
When replaying the SMF, be sure to replay from the top of the file.
6.
When the "COMPLETED! Please Power OFF." message appears on the
screen, turn off the SD-80's power.
7.
Remove the USB cable from the SD-80.
8.
Conduct the factory resetting as instructed in "RESTORING FACTORY
SETTING", then turn off the power.
9.
Perform the operations described in "Checking the version number", and
confirm that updating is correctly completed by checking the version
number.
13
Be sure to perform factory resetting after updating.
When using the MIDI-IN terminal
Necessary items
· SD-80 and AC power cord
· Sequencer that can replay the SMF (MC-80, MC-50mkII or equivalent)
· MIDI cable
· SD-80 Version Updating Disk (#17041156)
UPDATING PROCEDURE (BY MIDI)
1.
Connect MIDI OUT of the external sequencer and MIDI IN 1 of the SD-80
with the MIDI cable.
2.
While holding down the [SYSTEM], [PAGE <] and [PREVIEW] buttons,
turn on the power. The "Program Updater" message appears. Keep
holding down these buttons until the next screen appears.
fig.2-1_65
3.
Press the [PART<] button to open the "Updating by MIDI" screen.
fig.2-1b_65
4.
Press the [ENTER] button. The "Waiting ..." message appears, indicating
that the unit is waiting to receive MIDI data.
fig.2-2_65
5.
Replay the "f00001.mid" file on the SD-80 Version Updating Disk using
the external sequencer. The screen shows the progress during updating.
The "Receiving ..." message appears during the SMF replaying to
indicate that the SD-80 is in receiving mode.
fig.2-3_65
6.
When replaying of one file is completed, the "Waiting ..." message
appears. Replay the remaining SMF files in numerical order.
*
The SMF for MIDI updating (f00001.mid - f00032.mid) are saved on the SD-80
Version Updating Disk.
*
For sequencers that can perform chain-play, (e.g.MC-80) continuous replay in
numerical order makes updating easier
Do not turn off the power of the SD-80 during updating.
If the power is turned off, the board memories may be destroyed.
Note that the main board must be replaced in this case.
7.
When the "COMPLETE! Please Power OFF." message appears, turn off
the power of the SD-80.
8.
Conduct factory resetting as instructed in "RESTORING of FACTORY
RESETTING", then turn off the power.
9.
Perform the operations described in "Checking the version number", and
confirm that updating is correctly completed by checking the version
number.
Be sure to perform factory resetting after updating.