19 Set the SEG23 and SEG24 values:
a Set the SEG23 value by pressing the
value you want to set appears on the remote control display.
b Set the SEG24 value by pressing the
value you want to set appears on the remote control display.
When you press the
following order:
3 Check whether the option values that you have set are correct by pressing the
[SEG2, SEG3]
[SEG4, SEG5]
[SEG14, SEG15]
[SEG16, SEG17] 7 7
4 Save the option values into the indoor unit:
Point the remote control to the remote control sensor on the indoor unit and then press the
on the remote control twice. Make sure that this command is received by the indoor unit. When it is successfully
received, you can hear a short sound from the indoor unit. If the command is not received, press the
button again.
5 Check whether the air conditioner operates in accordance with the option values you have set:
a Reset the indoor or outdoor unit.
Indoor unit : Press the
seconds.
Outdoor unit : Press the K3 button.
b Remove the batteries from the remote control, insert them again, and then press the
remote control.
Steps
(Low Fan) button repeatedly until the
(High Fan) button repeatedly until the
(Low Fan) or
(High Fan) button, values appear in the
[SEG6, SEG8]
[SEG9, SEG10] 0 0
[SEG18, SEG20] 0 0
[SEG21, SEG22]
(Set) and
(Low Fan) buttons on the remote control simultaneously for 4
(Mode) button repeatedly
[SEG11, SEG12]
[SEG23, SEG24] 4 4
Remote control display
SEG23
SEG24
(Power) button