Barracuda CloudGen Firewall
Glowing
Color
State
Off
Off
Green
Blinking
Green
Steady
Red
Blinking
Red
Steady
Orange
Blinking
Orange
Steady
Acoustic Signal Frequency
Beep
Beep
3 times
Not all appliances support orange and/or red LED colors. Depending on the appliance type, the
status LED might be on by default and it might take some time during boot and installation to
start either blinking or changing the color. Furthermore, the status LED might blink at different
frequencies.
Serial Console Port
In order to establish a console connection to the appliance using a serial cable (Revision A: DB9, other
revisions: RJ45), you need to configure the serial port on the terminal using the following parameters:
Parameter Value
Baud
19200
Barracuda NG Firewall F600 Revision C
Meaning installation
Appliance is powered off or
installation has not initialized far
enough for LED control when
installation is started.
Normal installation.
Installation was completed
successfully, appliance is halted for
reboot or installation was not yet
initialized far enough for LED
control.
Error during installation.
-
-
-
1 time
Unit starts booting
Installation is completed successfully and appliance is halted for
reboot. After reboot, one beep indicates booting.
Meaning Normal Operation or
Active Recovery Technology

Operation

Appliance is powered off.
Appliance is either booting, shutting
down or performing a system update.
Barracuda NG Firewall is up and running.
An error has appeared preventing
Barracuda NG Firewall from entering the
up state.
If no orange light available: appliance is
in
ART
mode.
Appliance is halted and may be
disconnected.
-
Appliance is in
ART
Meaning Installation
mode.
5 / 8