Volvo Penta D1-13 Workshop Manual page 28

Group 30
Hide thumbs Also See for D1-13:
Table of Contents

Advertisement

30-2 Fault Tracing
P0005110
26
B
A
Measurements
Checking the fuel level sensor
Tools:
88890074 Multimeter
1
NOTICE! Cut the current with the main switch.
2
Remove the connector from the fuel level sensor.
3
Use 88890074 Multimeter to measure the resist-
ance between the two terminal pins on the level
sensor.
Nominal value
Empty tank (A)
Full tank (B)
4
Turn the main switch on.Turn the ignition on
5
Use 88890074 Multimeter to measure the voltage
between the two fuel level conductors from the
MDI. The fuel level sensor shall not be connected.
Measurement points
MDI fuel level output
47704383 06-2013 © AB VOLVO PENTA
R ≈ 3 ±2 Ω
R ≈ 180 ±15 Ω
Nominal value
U ≈ 5 V