D. Provide outlet velocity and fan's inlet sound power readings for the eight octave bands
decibels, and sones.
E. Strictly adhere to QUALITY ASSURANCE requirements as stated in section 1.04 of this
specification.
F. Provide manufacturer's certification that exhaust fans are licensed to bear Air Movement and
Control Association (AMCA), Certified Rating Seal for sound and air performance.
G. Installation, Operation, and Maintenance Manual (10M): Provide manufacturer's installation,
operations, and maintenance manual, including instructions on installation, operations,
maintenance, pulley adjustment, receiving, handling, storage, safety information and
cleaning. A troubleshooting guide, parts list, warranty and electrical wiring diagrams.
QUALITY ASSURANCE
1.4
A.
Performance ratings: Conform to AMCA standard 211 and 311. Fans must be tested in
accordance with ANSIIAMCA Standard 210-99 and AMCA Standard 300-96 in an AMCA
accredited laboratory. Fans shall be certified to bear the AMCA label for air performance
seal.
B. Classification for Spark Resistant Construction, levels A, Band C, conform to AMCA 99.
C. Each fan shall be given a balancing analysis which is applied to wheels at the outside radius.
The maximum allowable static and dynamic imbalance is 0.05 ounces (Balance grade of
G6.3).
D. Comply with the National Electrical Manufacturers Association (NEMA), standards for motors
and electrical accessories.
E. The High Wind models have been analyzed and stamped by a state license P.E. to the
ASCE 7-02 Standard which meets the IBC, Florida and Miami-Dade codes.
F.
Each High Wind model is subject to be certified by a third party to the ASTM E330 Static
Pressure Difference Standard.
G. All High Wind models have been analyzed using Computational Fluid Dynamics (CFD). The
CFD simulates the flow of high speed (150MPH) winds over the surface of objects.
H. The Finite Element Analysis (FEA) is the results from the CFD and it can accurately predict
the stress, strain, and deflection resulting form high wind loads.
1.5 DELIVERY, STORAGE, AND HANDLING
A.
Delivery: Deliver materials to site in manufacturer's original, unopened containers and
packaging, with labels clearly indicating manufacturer, material, products included, and
location of installation.
B. Storage: Store materials in a dry area indoor, protected from damage, and in accordance
with manufacturer's instructions. For long term storage follow manufacturer's Installation,
Operations, and Maintenance Manual.
C. Handling: Handle and lift fans in accordance with the manufacturer's instructions. Protect
materials and finishes during handling and installation to prevent damage. Follow all safety
warnings posted by the manufacturer.
WARRANTY
1.6
A. Manufacturer's Warranty: Submit, for Owner's acceptance, manufacturer's standard warranty
document executed by authorized company official. Manufacturer's warranty is in addition to,
and not a limitation of, other rights Owner may have under Contract Documents.
1.
The warranty of this equipment is to be free from defects in material and workmanship
for a period of one year from the purchase date. Any units or parts which prove
defective during the warranty period will be replaced at the Manufacturers option when
returned to Manufacturer, transportation prepaid.
2.
Motor Warranty is warranted by the motor manufacturer for a period of one year.
Should motors furnished by us prove defective during this period, they should be
returned to the nearest authorized motor service station.
CSI Specifications for Belt Drive Sidewall Mounted Centrifugal Exhaust Fan, Model-
Copyright
2010 Greenheck Fan Corporation
@
CWB (08/10)
'
Page 30f7