1.99
- Standards Handbook
2.
200 - Publication, Air Systems
3.
201-90 - Publication, Fans and Systems
4.
202-88 - Publication, Troubleshooting
5.
203-90 - Publication, Field Performance Measurement of Fan Systems
6.211-05
- Publication, Certified Ratings Program - Product Rating Manual for Fan Air
Performance
7.
300-96 - Standard Reverberant Room Method for Sound Testing of Fans
8.
311-05 - Publication Certified Ratings Program - Product Rating Manual for Fan Sound
Performance
9.
99-0401-86 - Classification for Spark Resistant Construction
10: 99-2408-69 - Operating Limits for Centrifugal Fans
B, Air Movement and Control Association Inc..(AMCA), American National Standards Institute
(ANSI):
1.
204-05 -Standard Balance Quality and Vibration Levels for Fans
2.
210-99 - Standard Laboratory Methods Of Testing Fans for Aerodynamic Performance
Rating
C. American National Standards Institute (ANSI):
1.
11-r1999 - Method of Evaluating Load Ratings of Bearings
D. American Society of Civil Engineers (ASCE):
1.
7-02 - Minimum Design Loads for Building and Other Structures
E. American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. (ASH RAE):
1.
Chapter 45 - 2003 Handbook, HVAC Applications
2.
Chapter 7 - 2001 Fundamentals Handbook, Sound-Vibration
3.
Chapter 32 - 2001 Fundamentals Handbook; DuctDesign
4.
Chapter 18 - 1992 HVACSystem and Equipment Handbook, Fans
F. American Society for Testing and Materials (ASTM):
1.
E330-02 - Standard Test Method for Structural Performance of Exterior Windows,
Doors, Skylight and Curtain Walls by Uniforl11Static Air Pressure Difference
G. National Fire Protection Association (NFPA)
1.
70 - National Electrical Code
2.
90A-02 - Standard for the Insta/lationof Air-Conditioning and Ventilating Systems
3.
92A-06 - Recommend Practice for Smoke-Control System
4.
92B-05 - Standard for Smoke Management System in Malls, Atria, and Large Areas
5.
96-04 - Standard for Ventilation Control and Fire Protection of Commercial Cooking
Operations
H. Occupational Safety and Health Administration (OSHA):
1.
1910.212 - General requirements for Machine Guarding
2.
1910.219 - General requirements for guarding safe use of mechanical power
transmission apparatus
3.
1926.300 - General requirements for safe operation and maintenance of hand and
power tools
I.
Underwriters Laboratories (UL):
1.
507 - Electric Fans
2.
555 - Fire Dampers
3.
555S - Smoke Dampers
4.
705 - Standard Power Ventilators
5.
762 - Standard Power Roof Ventilators for Restaurant Exhaust Appliances
6.
793 - Snow Load
1.3 SUBMITTALS
A. General: Submit in accordance with Section 01 3300 Submittal Procedures.
B. Provide dimensional drawings and product data on each fan.
C. Provide fan curves for each fan at the specified operation point, with the flow, static pressure
and horsepower clearly plotted.
CSt Specifications for Belt Drive Sidewall Mounted Centrifugal Exhaust Fan, Model-