Modem Connection
Hardware requirements
Description
Required for the SV8300
Required for the remote
unit
* Customer purchases
Connection method
STEP1: Using CAT or PCPro (RS-232C connection), set the following system data on the SV8300:
• CM08
First data
Second data : 0 (To use)
• CM40 YY=10
First data
Second data : X - XXXXXXXX (Station number)
• CM13 YY=07
First data
Second data : 0 (Data station)
• CM13 YY=18
First data
Second data : 0 (To send)
• CM15 YYY=044
First data
Second data : 0 (Restricted)
Quantity
COT blade
1
PC*
1 unit
Modem*
1 unit
RS-232C
1
straight cable
: 909
: 1
: X - XXXXXXXX (Station number)
: X - XXXXXXXX (Station number)
: 00 - 15 (Service control class A)
2-10
Chapter 2 Setting Up PCPro
Connecting PCPro to the SV8300
Remarks
• Used to interface the SV8300 to a
public network.
• For the specifications of the PC
required, see "Operating Environ-
ments and Conditions".
• Modem supporting AT commands
• 28.8 Kbps or faster modem recom-
mended
• Used to connect the modem and PC to
each other.
Page 1-3
NWA-033628-001 Rev.1.0