Special System Data Entered in the System Data Mode
This section describes the description of special system data (CM05, 10, 20, 90, 97, 9A) entered in the Sys-
tem Data Mode.
CM05
Y
No.
MEANING
0
Blade Type
1ST DATA
DATA
MEANING
XX ZZ
XX : Unit No. (01-50)
ZZ : Slot No. (01-18)
5-7
Chapter 5 System Data Mode
Using System Data Mode
2ND DATA
DATA
MEANING
10
Digital Line Circuit Blade for
Multiline Terminal/DSS
Console (CD-8DLCA/
CD-16DLCA)
20
Analog Line Circuit Blade for
Single Line Telephone
(CD-4LCA/CD-8LCA)
21
LLC (OPX) Blade
(CD-4DIOPA/CD-4DIOPB)
30
C.O. Trunk Blade (CD-4COTB)
31
OD Trunk Blade
(CD-4DIOPA/CD-4DIOPB)
32
Direct Inward Dialing Trunk
Blade (CD-4DIOPA/
CD-4DIOPB)
33
LD Trunk Blade
(CD-4DIOPA/CD-4DIOPB)
40
Basic Rate (2B + D) Interface
Trunk Blade (CD-2BRIA)
41
ISDN Primary Rate (23B + D/
30B + D) Interface Blade
(CD-PRTA)
42
CCIS (1.5 Mbps/2 Mbps)
Trunk Blade (CD-CCTA)
43
T1 (1.5 Mbps)/E1 (2 Mbps)
Digital Trunk Interface Blade
(CD-PRTA)
45
QSIG (CD-PRTA)
50
CS/ZT Interface Blade
(CD-4CSIB)
Continued on next page
NWA-033628-001 Rev.1.0