Secondary Air Tube Removal / Installation
1. Allow the stove to burn out and cool down, until cool to touch.
2. Open stove door to access secondary air tubes.
Note: to make it easier to remove the air tubes, first remove both the bottom
right base brick and right side wall brick.
3. Grasp secondary air tube firmly with vise grips, using a hammer tap vise
grips from right to left until air tube is released from grip. Remove.
4. Remove top left and right metal retainers, followed by the fragile three piece
C-Cast Baffles, then remove the remaining 2 tubes.
5. To reinstall or replace, first slide left side of tube into hole on left side air
Secondary Air
Tubes
channel. Align tab on right side air channel with notch on right hand end of
air tube. Firmly grip center of air tube with vise grips, use hammer to tap vise
grips from left to right until the tube bottoms out into the air channel on right.
Regency CI1150 Wood Cast Insert