Remove.the.battery; Connect.the.diagnostic.tool.-.Lihd60X./.Lihd70X; Signal.to.diagnostic.tool - Husqvarna LiHD50 Workshop Manual

Table of Contents

Advertisement

6 Diagnosis and troubleshooting
6.1 Remove the battery
Press in the catches and remove the battery.
See figure 1.
WARNING!
The battery must always be removed
for service/repair work and may only
be replaced once the machine has
been completely assembled again!
WARNING!
Do not short circuit the battery!
Never unscrew the battery!
Never fit a damaged battery!
Replace a damaged battery!
6.2 Connect the diagnostic tool -
LiHD60X / LiHD70X
1
Connect the adapter cable for the diagnostic tool to
the battery and the battery contact on the machine.
Connect cable (A) to the diagnostic tool for trouble-
shooting the machine.
Connect cable (B) to the diagnostic tool for trouble-
shooting the battery.
NB! Refer to the manual for the Diagnostic Tool
Battery for detailed instructions and follow the
instructions in the diagnostic tool.
See figure 2.
2
Diagnose/troubleshoot according to the diagnostic
tool instructions and make any necessary repairs
as instructed in the relevant chapter in this manual.
6.3 No signal to diagnostic tool
1
Check that the contact on the battery and the bat-
tery contact on the machine are intact and clean.
Replace the battery or alternatively the control
unit on the machine if there is any damage to the
contact.
2
Check that the cable to the diagnostic tool is intact
and clean. Replace the cable if it is damaged.
3
Restart the computer/Reinstall the software.
Diagnosis and troubleshooting
1
2
Fig.1
A
Fig.2
1
B
English
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lihd60xLihd70x

Table of Contents