THE HIGH VOLTAGE COMPONENTS
ACCESSING THE COMPONENTS
The components for service in this section
include the:
Magnetron
High Voltage Rectifier
High Voltage Capacitor
High Voltage Transformer
The locations of the high voltage components
are shown below. All of the high voltage com-
ponents are accessible through the front con-
trol panel cutout. However, the cabinet must
be removed to access the mounting screws for
the magnetron. Refer to the following pages
for servicing the high voltage components.
Disconnect from the electrical supply be-
fore servicing the unit. Failure to do so
could result in death or electrical shock.
Discharge the high voltage capacitor be-
fore working inside the oven. Failure to do
so could result in death or electrical shock.
MAGNETRON
HIGH VOLTAGE
CAPACITOR
2-26
WARNING
Personal Injury Hazard
HIGH VOLTAGE
RECTIFIER
HIGH VOLTAGE
TRANSFORMER