Whirlpool 1997 "E" Service Manual page 61

Over-the-range microwave oven hood combination 1997 “e” models
Table of Contents

Advertisement

COMPONENT
Convection Thermistor
Convection Heating Element
(with leads disconnected)
Gas Sensor
TEST PROCEDURE
Set the ohmmeter to the R x 10 K
scale.
Remove the 6-pin connector from
the circuit board and measure
across terminals 5 & 6.
Set the ohmmeter to the R x 1
scale, and measure across the
terminals.
Set the ohmmeter to the R x 1
scale.
Remove the 3-pin connector from
the circuit board and measure the
resistance between:
a) Red & white wire terminals.
b) White & yellow wire terminals.
3-21
Cooking Products Service Manual
Original March, 1997
© 1997 Whirlpool Corporation
RESULT
a) Normal = 155 K to 350 K
ohms @ 68˚F.
b) Abnormal = Infinity, or
zero ohms (a short).
a) Normal = 9 to 40 ohms @
68˚F ±2˚.
b) Abnormal = Infinity, or
zero ohms (a short).
a) 20 ohms @ 68˚F ±2˚.
b) Infinite.
4322167