3-2-4.

USB 1.1 Confirmation Check

Mode
Power Supply
Test Program
MemoryStick
CompactFlash
Microdrive
Specified Value
System requirements of the PC:
PC with the USB1.1 connector
Checking method:
1)
Disconnect the USB cable.
2)
Double click "My computer" icon on the PC and open "My
computer" screen.
3)
Check the drives displayed on the "My computer" screen. These
are the drives built in the PC.
4)
Turn on the power of HDPS-M10.
5)
Connect HDPS-M10 and USB1.1 connector of the PC using
the USB cable.
6)
Check that "HI-SPEED USB Device Plugged into non-HI-
SPEED USB Hub" message is displayed.
Note: This message is displayed when the operation system of the PC
is Windows XP.
7)
Check that the following three drives are newly displayed on
the "My computer" screen.
Note: The drive letters (e.g., "G:") differ depending on the PC.
Drive name
Local Disk (G:)
Removable Disk (E:) E
Removable Disk (F:) F
HDPS-M10
USB
AC power adaptor
Not necessary
Not necessary
Not necessary
Not necessary
Three drives should be newly
displayed
Fig. 3-1-13.
Drive letter Storage media
G
Hard Disk
Memory Stick
Micro Drive/Compact Flash
Fig. 3-1-14.
3-2-5.

Final Function 2 (USB Mode) Check

Mode
Power Supply
Test Program
MemoryStick
CompactFlash
Microdrive
Specified Value
Note1: When the storage media is checked, the data memorized on it will
be erased. After the check finishes, format the storage media again.
Note2: When the hard disk is checked, the data memorized on it will be
erased. After the hard disk check finishes, perform "3. HDD Self
Format" again.
Checking method:
1) Turn on the power of HDPS-M10.
2) Connect HDPS-M10 and PC using the USB cable.
3) Double click "strdevtst7.exe" of the "FC2_BI(r)" folder, and
start "Storage device test" on the PC.
4) Check that "Storage device test" screen is displayed.
5) Set up "Storage device test", as shown in the following table,
corresponding to the storage media.
Storage media
Memory
Stick PRO Flash
Drive name
E
(Note)
Read
No check No check No check No check
Write
Check
Random
Check
Verify
Check
Time out setting
256msec
Automatic
No check No check No check No check
If error occurred, ... No check No check No check No check
Note:
The drive names (e.g., "E:") differ depending on the PC.
6) Insert a storage media to be checked in the slot.
7) Click "Test Start" button.
3-8
USB
AC power adaptor
strdevtst7.exe
Blank Memory Stick PRO
Blank CompactFlash
Blank Microdrive
Memory Stick PRO:
Error rate = 0.000000E + 000
CompactFlash:
Error rate = 0.000000E + 000
Microdrive:
Error rate = 0.000000E + 000
Hard disk drive:
Error rate = 5.000000E – 002 or less
Fig. 3-1-15.
Compact
Microdrive Hard disk
F
F
G
Check
Check
Check
Check
Check
Check
Check
Check
Check
288msec
416msec
224msec

Advertisement

Table of Contents
loading

Table of Contents