Troubleshooting - Waring WSM10L Manual

10.0-quart/20.0-quart stand mixers
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSES
Mixer will not
Bowl guard not in closed position.
operate
Bowl not raised.
Power not connected properly.
Building circuit breaker is off.
Internal overload tripped.
Gear not engaged.
Mixer stops
Internal overload tripped.
during mixing
cycle
Mixer is noisy
Mixer is not installed on
level surface.
Bowl not seated correctly or
clamps not in place.
Agitator not fitted properly.
Overloading bowl.
Safety guard
seized (will
not move
freely)
Agitators
Lack of lubrication and/or
won't go onto
cleaning of the planetary shaft.
the planetary
shaft easily
Bowl lift
Lack of lubrication on bowl slides.
sticking or not
operational
One or more
Damaged or broken gear.
gears not
working
Mixer will not
Incorrect or low voltage.
mix medium
or heavy loads
ACTION REQUIRED
Rotate guard to the right until fully
closed.
Raise bowl to highest position.
Check all power connections. Plug into
a live socket. (Do not use extension cord!)
Test socket with another item.
Check breaker box.
Press STOP button, then press reset button
located on the back of mixer. Wait two
minutes. Then press START to restart mixer.
(If overload continues to trip, reduce batch
size and/or adjust recipe!)
Switch gear fully into position. (Mixer will
not operate if the speed control lever is
positioned in between speeds.)
Press STOP button, then press reset button
located on the back of the mixer. Wait two
minutes. Then press START to restart the
mixer. (If overload continues to trip, reduce
batch size and/or adjust recipe!)
Adjust surface or relocate mixer.
Make sure rubber feet are installed.
Make sure bowl is seated into bowl
cradle correctly, and bowl clamps are
locked into place.
Remove and attach agitator into position
properly.
Reduce batch size.
Refer to Capacity Chart section.
Clean & lubricate slide sheath.
Wipe planetary shaft with a clean, damp
cloth and lubricate the shaft with mineral
oil or food-quality grease.
Lubricate bowl slides with mineral oil or
food-quality grease. If still sticking,
technician must clean bowl-lift mechanism
Technician to replace gear.
Always stop mixer before shifting gears!
Contact electrician.
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wsm20l