  • Page 2: Safety Precautions

    Safety Precautions This section contains important information to help prevent damage to the user, other people, and to property. ● Understand the following indications and symbols before reading the rest of this manual, and follow the instructions. Explanation of indications Explanation of symbols indicates prohibited items.
  • Page 3: Cautions For Use

    Cautions for relocation and repairs If the air conditioner becomes submerged For repairs please contact your original in water due to high winds or flooding, retailer please contact your original retailer Request Request Relocation could result in malfunction, fire or If the unit is repaired incorrectly it could lead to fire electric shock.
  • Page 4 Safety Precautions (continued) Cautions for use Do not place flammable aerosols near the Do not place plants or animals somewhere air conditioner and do not spray them where the air from the air conditioner may onto the air conditioner hit them directly Prohibited Prohibited Doing so may adversely affect the plants or animals.
  • Page 5: Component Names

    Component Names Indoor Unit Duct type Air discharge Air Inlet Drain Pan Metal fitting Metal fitting Earth screw...
  • Page 6: Part Names And Functions Of The Remote Control

    Part Names and Functions of the Remote Control This remote control can control up to 8 indoor units. ● Buttons ● Once the settings have been configured, all you need to do is press the ON/OFF button. Operation lamp Lights up during running. Blinks when an error occurs or the protective device activates.
  • Page 7 All indicators are displayed in the display example below for reference. During use, only the selected options will Display be displayed on the screen. Note ● blinks on the display of the remote control the first time the leakage breaker is turned on. The initial settings are progressing ●The LCD may temporarily become blurred due to static electricity.
  • Page 8: Correct Usage

    Correct Usage When you use the air conditioner for the first time or change the settings, follow the procedures below. From the next time, pressing the ON/OFF button will run the air conditioner with the chosen settings. Turn on the circuit breaker and leakage breaker Note When turned on, the separation line ●...
  • Page 9: Timer Operation

    Timer Operation Select a timer type from the following: (Max. 168 hours) OFF timer Repeat-OFF timer ON timer Stops running after the specified period. Stops running after the specified period every Starts running after the specified period. time you use the air conditioner. Setting the timer Push the [ ] button.
  • Page 10: Installation

    Installation Location Caution Make sure there is no risk of flammable gas Confirm that the outdoor unit is fixed on the base leakage Otherwise, the unit may fall down or other accidents may occur. Gas leaking and accumulating around the unit may cause a fire.
  • Page 11: Air Conditioner Operations And Performance

    Air Conditioner Operations and Performance Check before operation Protective device (high pressure switch) Turn on the power switch at least 12 hours before The high pressure switch stops the air conditioner automatically ● starting operation. when an excessive load is applied to the air conditioner. Make sure the earth wire is securely connected.
  • Page 12: Daily Maintenance

    Maintenance Be sure to turn off the main power switch prior to the maintenance. Caution Do not press buttons with wet hands Doing so may result in electric shock. Prohibited Daily maintenance Cleaning the air filters ●When the filter indicator is displayed on the remote control, clean the air filters.
  • Page 13: Appropriate Use

    Appropriate Use To save energy and achieve comfortable heating and cooling When cooling, do not let direct sunlight into Place TVs, radios, stereos etc. over 1 m away the room. from the indoor unit and/or remote control (sold separately) Hang curtains or blinds at the windows. ●...
  • Page 14: Troubleshooting

    Troubleshooting Check the points described below before asking for repair. Symptom Cause Cold white mist or water comes ● The fan of the outdoor unit have stopped automatically and defrosting is being performed. out. Occasionally there is a ● The solenoid valve makes this sound when defrosting starts or finishes. shushing sound.
  • Page 15: Failure Diagnosis

    After confirmation, press the TEST button to return to the usual display. Separately Sold Accessory Devices Warning Use only products specified by Toshiba. Use of a non-dedicated product may result in fire, electric shock, or water leakage. Ask an expert to install it.
  • Page 16: Specifications

    Specifications 1601HA / D 1601HA / D 1601HA / D 1601HA / D 1601HA / D Model name RDA-S 015-ME 022-ME 037-ME 055-ME 075-ME Cooling capacity (*1) 43.2 44.8 44.8 44.8 46.5 Cooling capacity (*2) 31.9 33.0 33.0 33.0 34.2 Heating capacity 49.2 50.0...
  • Page 17 2001HA / D 2001HA / D 2001HA / D 2001HA / D 2001HA / D Model name RDA-S 015-ME 022-ME 037-ME 055-ME 075-ME Cooling capacity (*1) 52.1 54.7 56.0 56.0 57.3 Cooling capacity (*2) 35.0 36.7 37.6 37.6 38.5 Heating capacity 61.8 62.5 62.9...
  • Page 18 Specifications (continued) 2401HA / D 2401HA / D 2401HA / D 3001HA / D 3001HA / D 3001HA / D Model name RDA-S 037-ME 055-ME 075-ME 037-ME 055-ME 075-ME Cooling capacity (*1) 66.3 67.2 67.9 82.1 84.0 84.0 Cooling capacity (*2) 48.8 49.5...